Sep.2026 09
Views: 1191
Annex III and IV Performance and Durability: The Cycle-Life Parameters EU Buyers Now Request
Introduction
Portable rechargeable batteries must disclose, then meet, electrochemical performance and durability parameters. Paper A translates Annex III/IV into cycle-life, internal-resistance and efficiency tests for NiMH.
Details

Annex III and IV performance and durability parameters for NiMH batteries

Regulation (EU) 2023/1542 is the first EU battery law to regulate performance and durability, not only safety and substances. Article 9 with Annex III covers portable batteries (excluding button cells in the general-purpose case), Article 10 with Annex IV covers LMT, SLI and industrial batteries, and both follow a disclose-then-threshold logic. This paper translates the parameter lists into a nickel-metal hydride (NiMH) test and specification program.

The Disclose-Then-Threshold Logic

From 18 August 2024, manufacturers of general-purpose portable rechargeable batteries must make electrochemical performance and durability parameters available with the product; binding minimum thresholds apply from 18 August 2027 or 18 months after the delegated act setting them, whichever is later. For rechargeable industrial batteries above 2 kWh, parameters have been available since 18 August 2024 and binding thresholds follow from 18 August 2028. The disclosure-first design gives industry time to align test methods, but buyers — especially medical, industrial and public-procurement accounts — already request the parameter sheet at quotation stage.

animated bars of illustrative NiMH durability parameters cycles internal resistance efficiency

The Annex III Portable Parameter Set

Annex III asks for: rated capacity and the capacity retained after a defined number of charge-discharge cycles; internal resistance (or impedance); the charging and discharging conditions under which the values are measured; the expected lifetime under reference conditions, including cycle count to a defined capacity-fade endpoint (commonly 80 % of rated capacity); and, where relevant, performance at temperature extremes. For NiMH the underlying methods already exist in IEC/EN 61951-2 (sealed nickel-metal hydride cells and batteries) and IEC 61436/61951 family standards: standard charge at 0.1 C for 16 hours, discharge at 0.2 C, cycle life under controlled temperature, and internal resistance by the AC milliohm method. A defensible datasheet cites the exact charge/discharge regime, ambient temperature and fade endpoint rather than a bare "500 cycles" claim.

Annex IV for Industrial NiMH Packs

Annex IV extends the set for LMT, SLI and industrial batteries with round-trip energy efficiency and its evolution over cycles, power capability at defined state of charge and temperature, calendar-aging behaviour, self-discharge rate and expected lifetime under defined duty profiles. For large NiMH backup and traction packs this means recording the reference duty cycle (float standby, periodic deep discharge, high-rate pulse), the float-voltage and temperature regime, and the capacity-check interval. NiMH ageing is heat-driven: the same pack loses capacity at very different rates at 20 °C versus 40 °C float, so durability claims without a temperature condition are meaningless under the Regulation's evidence standard.

animated capacity retention curves for matched and budget NiMH cells across cycles

How the Parameters Are Verified

Conformity assessment under Module A requires the parameters to be traceable to test records: lot samples cycled to the fade endpoint, internal-resistance distributions with statistical limits, efficiency measured by integrated charge/discharge energy, and self-discharge measured after defined storage. Low-self-discharge (LSD) NiMH cells add a retention test after 12 months at 20 °C. Series packs require cell-matching data because the weakest cell governs pack cycle life; a credible supplier reports the matching band (capacity ±2–3 %, resistance ±10 %) and the welding/assembly controls that preserve it.

What European Buyers Actually Do With the Data

Procurement engineers use the durability sheet for three decisions: warranty reserves (cycle count and fade define replacement rates), total-cost comparison against primary cells and competing chemistries, and service-interval planning for sealed devices. Missing or vague durability data pushes a supplier toward the "unverified" tier regardless of price. Conversely, a supplier who can show cycle curves at two temperatures, resistance distributions and lot-to-lot consistency wins design-ins precisely because the buyer can defend the choice in its own Annex III/IV documentation.

Weijiang Power

Weijiang Power ships every NiMH family with an Annex III/IV-aligned durability pack: rated and post-cycle capacity to the 80 % fade endpoint under cited IEC 61951-2 regimes, AC internal-resistance distributions, self-discharge and temperature-conditioned cycle curves, and cell-matching bands for welded series strings. Send your duty profile, expected service life and operating temperature window and we return the parameter sheet with the underlying test records for your technical file.

Lastest News
Unlock the power of lithium batteries for lasting performance in handheld vacuum cleaners. Weijiang Li-on Battery leads the charge in innovation.
READ MORE
A NiMH battery pack is a collection of individual NiMH batteries connected in series or parallel to create a higher voltage or capacity battery.
READ MORE
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Name*
Whatsapp/Phone
Email*
Message*
Professional battery factory, support OEM & ODM customization.
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Company Name*
Email Address*
WhatsApp / Phone*
Message & Requirements*

Buyer fact sheet

Weijiang Power at a glance

Legal entityShenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power
Founded2010, 16 years of NiMH battery manufacturing
FactoryHuizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops
Capacity200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors
Product rangeNiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells
CertificationsCE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs
Markets60+ countries, focus on Europe and the United States
Order termsNo strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days
Medical NiMHMedical NiMH battery page

Quick answers for buyers

Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.

What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.

Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.

What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.

How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.

Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ

Language versions: Deutsch · Français · Español

Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.