This is Paper B of the C04 note on military training and target drone equipment, taking the load profiles from Paper A and turning them into a concrete pack decision: which of the ground roles the battery serves, which chemistry, how many cells, what nameplate capacity, and what margin the fleet needs to run a full training day. The sequence follows the way an engineer actually works - define the machine and the reuse model, choose the chemistry against the legacy lead-acid box and the frontline primary-lithium case, fix the cell configuration for the voltage the equipment accepts, build a pulse-duty capacity equation that separates the motor pulses from the idle electronics, apply cold and end-of-life deratings, and then define the multi-bay charging and protection arrangement. Two worked examples are shown end to end: a 24 V pop-up actuator pack that replaces a legacy 24 V / 8 Ah lead-acid box, and a small cell for a portable laser target or hit sensor. Every number in them is labelled illustrative and built from currents and timings in the range of published equipment, not a specification for a named product; the binding values for a real project remain the device manual and the agreed pack drawing.
Key fact 1. The first decision is which ground role the pack serves, not the cell count. There are three honest sealed NiMH roles on a training range: the ground pop-up, rising and swing target actuator pack at the 24 V class that replaces a lead-acid box, the MILES and laser-engagement electronics and accessories that run on small cells, and the fixed-site controllers, telemetry and ground-control-station support backup. Aerial target propulsion is excluded from the start because flight uses high-rate lithium and full-size targets are turbine aircraft.
Key fact 2. A 24 V-class NiMH pack is twenty cells in series. Each sealed nickel cell is 1.2 V nominal, so twenty cells give 24 V nominal, about 29 V fully charged and 20 V at the end of discharge, which matches the voltage window of the legacy 24 V lead-acid box built from twelve 2 V cells. Parallel strings are added where the geometry needs more capacity, and the chosen count must sit inside the equipment's accepted input across the full discharge.
Key fact 3. The actuator load is a pulse-duty sum rather than a steady current. In the illustrative example a 10 A motor pulse lasting 1.2 seconds, applied twice per cycle for up and down, accumulates to about 5.33 Ah across 800 cycles in an eight-hour day, while a 0.12 A idle current for the detection and radio electronics adds about 0.90 Ah, giving a mission charge of roughly 6.23 Ah.
Key fact 4. The nameplate must exceed the mission number because usable capacity shrinks. Illustrative cold and end-of-life factors of 0.9 and 0.85 leave a usable fraction of 0.765, so the required nameplate is 6.23 divided by 0.765, or about 8.14 Ah - an 8 Ah-class 24 V pack that lands on the legacy 24 V / 8 Ah box geometry. The same 10 A pulse at 24 V is a 240 W peak, which the pack must deliver repeatedly without a damaging voltage sag.
Key fact 5. The rechargeable case is a fleet logistics system. Separable battery boxes with a charge display swap on a multi-bay base that can handle up to ten packs, and the charger terminates on the nickel negative-voltage-change or temperature-rise signal. Low-self-discharge cells hold charge between sessions, and pack-level protection - a PTC and a resettable fuse - is sized to the real pulse load rather than a generic peak.
The first design decision is what the battery actually powers and whether the equipment comes back. A ground pop-up, rising or swing target is a fleet machine with a separable battery box: the motor moves a plate that can weigh five kilograms or more through short pulses, and the box is swapped and recharged after the exercise. MILES weapon simulators, laser targets and hit sensors are worn or portable electronics that draw small currents over long sessions and turn over on a schedule. The fixed control station, telemetry and reporting equipment are mains or Power-over-Ethernet units that use a battery only to ride through a short interruption. Each is a repeated-use training, garrison or depot asset, which is the condition under which a rechargeable nickel pack pays off.
The reuse model is what separates these roles from the frontline and from flight. A machine that returns after every exercise and recharges on a defined schedule rewards a durable, not-restricted cell that removes disposable waste and lead-acid maintenance; a single-use frontline device or a weight-limited airframe does not. The honest boundary from Paper A is carried through this whole step: the pack is not offered as target-drone propulsion, and the mission profile, temperature and required runtime are recorded from the actual equipment rather than inferred from a competitor headline.
With the role fixed, the chemistry is chosen against the legacy product and the operating reality. The ground actuator has historically used a sealed lead-acid box, which is cheap but contains liquid, needs maintenance, gives only about 200-500 cycles and loses more of its capacity under high pulse currents through the Peukert effect. A sealed NiMH pack at the same 24 V class has no liquid and no routine maintenance, holds a flat voltage with little loss under the repeated pulses, and cycles roughly 500-1,000 times. For the small MILES electronics the comparison is instead against a disposable primary lithium, which is the right frontline choice for extreme cold and long storage but is wasted on equipment that returns and recharges; the honest reference cold limit for NiMH is around -20 C against roughly -40 C for primary lithium.
| Chemistry | Nominal voltage | Reference behaviour | Typical role |
|---|---|---|---|
| Sealed lead-acid (legacy) | 2 V per cell | About 200-500 cycles; liquid, maintenance, higher Peukert loss | Legacy 24 V / 8 Ah target box |
| Sealed NiMH (LSD) | 1.2 V per cell | About 500-1,000 cycles; no liquid, flat voltage, low Peukert loss | Rechargeable actuator and electronics packs |
| Primary lithium | Disposable cell | Reference to about -40 C; long shelf life; single use | Frontline extreme-cold and long-storage tasks |
| High-rate LiPo / Li-ion | High-rate rechargeable | High energy and discharge rate; flight propulsion, not a ground role | Electric target drones (excluded here) |
Weijiang does not manufacture lithium-ion cells in any case; any lithium work is pack assembly only and follows the lithium transport rules rather than the nickel path. The chemistry comparison below is meaningful only at the same duty cycle and temperature, which is why the design collects the real pulse pattern before choosing rather than comparing headline capacities.
Once the chemistry is set, the configuration follows the voltage the equipment accepts. A 24 V-class actuator pack stacks twenty 1.2 V cells in series, giving 24 V nominal; the same pack reaches about 29 V fully charged at 1.45 V per cell and falls to 20 V at the 1.0 V end-of-discharge point, which brackets the legacy 24 V lead-acid window. The critical check is that the motor controller and the electronics accept that range across the full discharge, including the lower end, so an early cutoff does not strand usable charge. Parallel strings are added where a single string cannot reach the required capacity, and the housing, retention and contacts are those of the separable battery box rather than a generic holder.

The smaller MILES devices use much shorter strings. A portable laser target or weapon simulator may run from two to four cells for 2.4-4.8 V, or from a single small cell where the manual confirms a 1.2 V input, and the geometry follows the host device rather than a standard holder. In every configuration the series count is set by the accepted voltage and the parallel capacity by the mission charge, rather than the other way around.
A ground actuator does not draw a steady current, so the mission charge is built as a duty-weighted sum of the motor state and the idle state. Taking an illustrative 10 A motor pulse lasting 1.2 seconds and two movements per cycle, one cycle uses 24 ampere-seconds of motor charge. Across an eight-hour day of 800 cycles the motor is on for 1,920 seconds, which is 10 times 1,920 divided by 3,600, or about 5.33 Ah. The remaining 26,880 seconds are idle; at an illustrative 0.12 A for the controller and radio that is 0.12 times 26,880 divided by 3,600, or about 0.90 Ah. The mission charge is therefore 5.33 plus 0.90, or roughly 6.23 Ah.
The endpoints matter as much as the total. The motor dominates the charge even though it is on for only a small fraction of the day, because each pulse is a high current, so a target that pops more often than planned moves the mission charge upward even though the eight-hour length is unchanged. The 10 A pulse at 24 V is a 240 W peak that the pack must deliver repeatedly, and the actual pulse current, timing and cycle count are collected from the equipment before sizing rather than assumed. The same method on a lower-current machine simply substitutes its real pulse and idle values.

The mission number is usable charge, but the pack must be larger because two effects reduce what it delivers. Cold slows the electrochemical reaction and lowers effective capacity, and over the service life the cells lose capacity through cycling and ageing. The design applies derating factors for both and keeps a margin. In the illustrative example factors of 0.9 for cold and 0.85 for end of life leave a usable fraction of 0.765, so the required nameplate is the 6.23 Ah mission charge divided by 0.765, or about 8.14 Ah - an 8 Ah-class pack that reuses the legacy 24 V / 8 Ah box geometry rather than forcing a new enclosure. The factors are cell and vendor dependent and agreed rather than assumed.
Where the mission approaches the coldest edge, the honest choice is primary lithium rather than a nickel pack, because the reference cold rating for NiMH sits near -20 C against roughly -40 C for primary lithium. The derating is applied as a division when sizing to a target mission, since multiplying would pick a pack too small; the same 0.765 used in reverse shows that an 8 Ah nameplate delivers about 6.1 Ah of usable charge, which is the consistency check against the 6.23 Ah requirement.
A rechargeable target fleet is only practical with a defined charge regime because overcharge heats nickel cells. A multi-bay base that can charge up to ten separable boxes at once terminates on the negative voltage change or temperature rise characteristic of nickel chemistry and schedules the turnaround of a fleet across an exercise. Low-self-discharge cells retain their charge between sessions so a box pulled from the rack is not flat, and the charge or voltage display on each box lets crews confirm the state before it is issued. The design checks the cell temperature under charge and repeated pulse discharge and confirms the voltage stays above the controller cutoff at the end of the pulse.
Protection is built into the assembly rather than added at the device. A PTC limits current under fault or overtemperature, a resettable fuse covers overcurrent, and the pack geometry and retention keep the contacts secure under the shock and vibration of a busy range. The protection is sized to the real 240 W pulse and the idle load rather than a generic peak, and the enclosure is the host battery box's defined shape with its separable contacts and display. Because the pack ships as a sealed nickel product rather than a lithium one, it follows the not-restricted nickel transport path rather than the lithium rules.
The low-current MILES role shows how the same method behaves at a much smaller scale. A portable laser target or hit sensor spends most of its time in a shallow standby and wakes only to register a short laser event, so an illustrative average current of 30 mA is a reasonable planning value rather than a measurement of one product. On a 600 mAh small pack the nominal runtime is 600 divided by 30, or 20 hours. Applying cold and end-of-life factors of 0.85 each leaves a usable fraction of 0.7225, giving a practical runtime of about 14.45 hours, which matches the roughly fifteen-hour accessory figures seen in fielded simulators.
The 100-hour MILES goal is best read as a design and logistics target rather than a single-cell requirement. At 30 mA, 100 hours would need 3 Ah of charge, which is large for a wearable device; the operational requirement therefore drives low-power electronics and a rechargeable turnaround on a schedule rather than one large disposable cell. The small nickel pack removes the cost and waste of disposables across a fleet of accessories while staying a not-restricted, abuse-tolerant product, and the exact current and runtime always come from the device manual.
| Design input | Why it is needed |
|---|---|
| Ground role and reuse model | Actuator, MILES electronics or support backup; confirm the equipment returns and recharges |
| Chemistry and temperature | Match NiMH against lead-acid and primary lithium; honour the about -20 C cold limit |
| Series count and parallel capacity | Twenty-series for 24 V; add parallel strings to reach the mission charge |
| Pulse current, timing and cycle count | Build the motor plus idle capacity equation and the 240 W peak |
| Cold and EOL deratings | Set the usable fraction and the 8 Ah-class nameplate margin |
| Charging and protection | Multi-bay turnaround, PTC and resettable fuse sized to the real pulse |
The sizing method applies wherever a sealed nickel pack is a genuine fit, and the scope is stated plainly rather than stretched. Sealed NiMH is not offered as a target-drone flight battery, where high-rate lithium is the correct chemistry, and it has no propulsion role on a full-size jet target. The realistic applications are the ground pop-up, rising and swing target actuator packs that replace a 24 V lead-acid box, the small MILES and laser-engagement electronics and accessories that turn over on a schedule, and the fixed-site controllers, telemetry and ground-control support backup where abuse tolerance and not-restricted shipping matter. All of these are repeated-use training, garrison and depot equipment that returns and recharges. At the frontline, where extreme cold and single-use missions dominate, the honest choice is primary lithium rather than a nickel cell, and no claim is made that NiMH outperforms it on those coldest tasks.
Because each sealed nickel cell is 1.2 V nominal, so twenty cells in series give 24 V. The same pack reaches about 29 V fully charged and 20 V at the end of discharge, which brackets the legacy 24 V lead-acid window built from twelve 2 V cells. Parallel strings are added where more capacity is needed, and the equipment must accept the full 20-29 V range.
The charge is a duty-weighted sum, not a function of on-time alone. In the illustrative example the 10 A pulses accumulate to about 5.33 Ah across 800 cycles even though the motor is on for only 1,920 seconds, and the 0.12 A idle adds about 0.90 Ah, giving a 6.23 Ah mission. The high pulse current is why the motor dominates the charge despite its short on-time.
Because only a fraction of the nameplate is usable. Cold and end-of-life factors of 0.9 and 0.85 leave 0.765 available, so an 8.14 Ah nameplate is needed to deliver the 6.23 Ah mission - an 8 Ah-class pack that reuses the legacy 24 V / 8 Ah box. The factors are vendor dependent, and sizing divides by the usable fraction rather than multiplying.
At an illustrative 30 mA average, a 600 mAh pack gives 20 hours nominal and about 14.45 hours after a 0.7225 derating, matching the roughly fifteen-hour accessory figures. The 100-hour MILES goal would need about 3 Ah at 30 mA, which is why it drives low-power design and rechargeable turnaround rather than one large disposable cell.
Lead-acid is cheap but carries liquid, needs maintenance, gives only about 200-500 cycles and loses more capacity under high pulse currents. A sealed NiMH pack at the same 24 V class removes the liquid and maintenance, holds a flat voltage with little Peukert loss and cycles roughly 500-1,000 times, while reusing the same separable box geometry and multi-bay charging workflow.
The equipment taxonomy and duty assumptions draw on published military and manufacturer references covering ground pop-up, rising and swing target machines and their separable battery boxes, multi-bay chargers, MILES and laser-engagement accessories and ground-control-station requirements. The chemistry ranges - about 500-1,000 cycles for sealed NiMH against 200-500 for lead-acid, and the reference cold ratings near -20 C for NiMH against roughly -40 C for primary lithium - are typical published values rather than measurements of a named product, and the 10 A pulse, 0.12 A idle and 800-cycle mission in the worked examples are illustrative values shown as calculations rather than product specifications. Nickel cells and packs are qualified to IEC 61951-2 and IEC 62133-1 and ship under UN 3496 with the IATA A199 not-restricted air path, environmental qualification follows MIL-STD-810 and MIL-STD-461, and laser safety follows 21 CFR 1040 with MIL-STD-1425. No statistics have been invented.
Weijiang Power supplies sealed NiMH cells and assembled NiMH packs for the ground target actuators, MILES and laser-engagement electronics and range support backup of military training programs, built at the 24 V and smaller classes to the device geometry with PTC and resettable-fuse protection. The cells are qualified to IEC 61951-2 and IEC 62133-1 and the packs ship under UN 3496 with the not-restricted air path under IATA A199. We do not present NiMH as a target-drone flight battery, and we do not manufacture lithium-ion cells; lithium work is pack assembly only. Send us your equipment type, nominal voltage, motor or electronics current, pulse timing and duty cycle, expected temperature and charging arrangement, and we will work through the chemistry match, cell count, derated capacity and pack design and support the evidence for your evaluation. See the Weijiang NiMH product range for standard pack formats, or contact our OEM team with the device specification and load profile.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.