A vacuum pack is certified as part of a system, not as a cell in a box. The cell has its own performance and safety standards; the pack has a pack safety standard; the appliance has an appliance safety standard; the charger, EMC, ingress protection and transport add further layers. A test report that covers only the cell does not certify the pack, and a pack report that ignores the appliance's abnormal tests does not certify the vacuum. This paper sets out the four-layer evidence chain and the factory audit that keeps it valid.
A complete technical file should show four layers. Each answers a different question, and each has its own sample requirements, test conditions and acceptance criteria.
| Layer | Standard | Question answered | Typical evidence |
|---|---|---|---|
| Cell performance | IEC 61951-2:2017 + A1:2022 | Does the cell deliver the claimed capacity, rate and cycle life? | Capacity, high-rate discharge, cycle life, storage, internal resistance |
| Pack safety | IEC 62133-1:2017 (and 2026 edition where applicable) | Is the assembled battery safe under abuse and normal use? | External short, impact, crush, overcharge, forced discharge, thermal abuse |
| Appliance safety | IEC 60335-2-2:2019 / 2026, with IEC 60335-1 | Is the vacuum safe in normal and abnormal operation? | Heating, leakage, abnormal operation, motor stall, charging, mechanical hazards |
| System compliance | EMC, IP, environmental, transport | Does the product meet market and logistics requirements? | CISPR 14-1/-2, IEC 60529, IEC 60068, UN 3496 / IATA A199 |
IEC 61951-2 covers sealed nickel-metal-hydride cells for portable applications. It defines capacity, high-rate discharge, endurance and storage tests. The standard is a performance anchor: it tells the designer what the cell should deliver under defined conditions, not whether the assembled pack is safe. A cell that passes capacity at 0.2 C may still be unsuitable for a 10 C vacuum load.
IEC 62133-1 covers sealed NiMH cells and batteries. The pack tests are designed to reproduce abuse that can occur in service or logistics: external short circuit, impact, crush, overcharge, forced discharge and thermal abuse. The exact sample size, thermocouple placement and acceptance criteria are defined in the standard; a generic “UN 38.3 pass” is not a substitute.
| Test | What it stresses | Design lesson |
|---|---|---|
| External short circuit | High current through external path | Fuse, connector, wire gauge and cell tab must survive without fire |
| Impact / crush | Mechanical deformation of cells | Cell spacing, enclosure stiffness and internal support matter |
| Overcharge | Charger failure or wrong charger | Termination backup, temperature sensing, charge current limit |
| Forced discharge | Cell reversal in a series string | String protection, cutoff and cell matching |
| Thermal abuse | External heat or internal fault | Separators, venting and enclosure material |
The 2026 edition of IEC 62133-1 exists and should be checked against the destination market and the customer's technical file. The 2017 edition is still widely cited in existing certificates; a new project should not assume that an old report is accepted indefinitely. The standards edition is a commercial variable, not only a technical one.

IEC 60335-2-2:2019 is the seventh edition for vacuum cleaners and water-suction cleaning appliances. It covers battery-operated appliances, automatic battery-operated cleaners and motorised cleaning heads. The 2026 eighth edition aligns with IEC 60335-1:2020 and adds requirements for multi-phase central vacuum cleaners, blowing and inflating functions, docking stations and spray extraction appliances. A cordless vacuum project should confirm which edition the destination market currently applies.
| Appliance test area | Typical stress | Battery interaction |
|---|---|---|
| Normal heating | Continuous eco or normal mode | Cell and connector temperature rise |
| Abnormal airflow | Blocked filter or sealed inlet | Reduced motor cooling; possible current increase |
| Brushroll stall | Hair or carpet jam | High current pulse; connector and fuse stress |
| Charging fault | Wrong charger or failed termination | Overcharge, cell heating, venting |
| Drop | Handheld or stick vacuum falls | Cell displacement, weld fatigue, enclosure crack |
The charger is a separate safety and EMC subject. IEC 60335-2-29 covers battery chargers for household and similar use. EMC for the vacuum and charger typically follows CISPR 14-1 for emission and CISPR 14-2 for immunity, with the relevant EN versions for the EU. A bare NiMH pack is not an EMC product, but the charger, motor drive and any wireless module are.
| Requirement | Standard / method | Scope |
|---|---|---|
| Charger safety | IEC 60335-2-29 | Mains charger, output isolation, abnormal charging |
| Emission | CISPR 14-1 / EN 55014-1 | Motor drive, charger, electronics |
| Immunity | CISPR 14-2 / EN 55014-2 | ESD, surge, transient, RF fields |
| Ingress protection | IEC 60529 | IPX4 for wet-dry and outdoor use; IP5X for dust |
| Vibration | IEC 60068-2-6 | Transport and floor-head vibration |
| Drop | IEC 60068-2-31 | Handheld drop, pack retention |
| Thermal shock | IEC 60068-2-14 | Storage and shipping temperature cycling |
Wet-dry vacuums add a water path that a dry vacuum does not have. The pack may be remote from the water, but the connector, switch and charger dock are not. IPX4 is a common target for splash resistance; IPX6 may be requested for wash-down areas, but it must be tested with the pack installed and the connector mated. Cleaning agents can attack plastics, seals and plating; the chemical compatibility of the enclosure and connector is part of the design, not a purchasing detail.
| Exposure | Target | Test condition | Design response |
|---|---|---|---|
| Splash | IPX4 | Oscillating spray, pack installed | Sealed connector, gasket, drain path |
| Wash-down | IPX6 | Strong jet, connector mated | Double seal, protected vent, corrosion plating |
| Dust | IP5X | Dust chamber | Filtered vent, tight enclosure |
| Cleaning agent | Compatibility | Soak and wipe, repeated cycles | Material selection, label resistance |
Vacuum packs are handled, dropped, knocked against furniture and stored in vehicles. The pack should be qualified for the drop height and vibration profile of the product, not only for a generic battery test. A 1 m drop onto concrete is a common handheld target; a stick vacuum may see a different moment because the pack is at the handle or the floor head. The mounting method matters as much as the cell.

Nickel-metal-hydride batteries are not lithium-ion batteries, but they are still regulated for some modes. UN 3496 applies to nickel-metal-hydride batteries shipped by sea under the IMDG Code, Class 9. Air transport commonly uses IATA A199, which classifies the batteries as “Not Restricted” when the conditions are met; the air waybill should show “Not Restricted” and A199, and the air description should not use UN 3496. Road and ADR transport is generally not regulated for NiMH, but the carrier's own rules and the destination country's requirements should be confirmed.
| Mode | Common classification | Documentation | Caution |
|---|---|---|---|
| Sea (IMDG) | UN 3496, Class 9 | Dangerous goods declaration where required | Packaging, marking and segregation rules apply |
| Air (IATA) | A199 “Not Restricted” when conditions met | Air waybill “Not Restricted” + A199 | Do not use UN 3496 in the air description |
| Road (ADR) | Generally not regulated for NiMH | Carrier confirmation | National rules and carrier policy may differ |
| Postal / courier | Carrier-specific | Safety data sheet and declaration | Some carriers refuse loose batteries |
| Market | Safety route | EMC / wireless | Battery / transport |
|---|---|---|---|
| EU | CE, Low Voltage Directive or appliance safety, IEC 60335-2-2 | EMC Directive, CISPR 14-1/-2 | Battery Regulation (EU) 2023/1542, UN 3496 sea / A199 air |
| UK | UKCA, BS EN 60335-2-2 | UK EMC regulations | UK battery and transport rules |
| USA | UL 1017 or equivalent, IEC 60335-2-2 as technical basis | FCC Part 15 for charger / wireless | DOT / IATA rules; UN 38.3 not applicable to NiMH but carrier rules apply |
| Japan | PSE for charger, appliance safety | VCCI where applicable | METI / carrier requirements |
| Korea | KC safety certification | KC EMC | KC battery safety where applicable |
| Australia | RCM, AS/NZS 60335-2-2 | RCM EMC | ACMA / carrier rules |
| Audit item | Sampling | Acceptance record |
|---|---|---|
| Cell incoming | Every lot | Capacity, resistance, visual, date code |
| Weld pull | 5 per shift | Force and nugget size within spec |
| Pack capacity | 100% | Within tolerance band and cutoff |
| Thermistor | 100% | Position and response within spec |
| Drop / vibration | Per model per quarter | No cell displacement or connector loss |
| Marking | 100% | Legible, correct, traceable |
Certification is a chain of evidence, not a single certificate. The cell performance report, the pack safety report, the appliance safety report and the system compliance file each answer a different question. A NiMH vacuum pack is credible when the four layers are aligned, when the charger is treated as part of the battery system, and when the factory can reproduce the tested configuration. The next paper moves to a different cleaning platform: floor scrubbers and robotic cleaners, where traction and water loads change the duty profile.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | English medical NiMH page German medical NiMH page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.