Nov.2026 24
Views: 109
Testing and Certifying Sealed NiMH Packs for Floor Scrubbers and Robotic Cleaners: IEC 60335-2-10, IEC 60335-2-2, IEC 62133-1, IP and Transport
Introduction
Certification roadmap for floor scrubber and robotic cleaner NiMH packs: IEC 60335-2-10:2021, IEC 60335-2-2:2026, IEC 62133-1, IPX, EMC, mechanical tests, transport and factory audit.
Details

Testing and Certifying Sealed NiMH Packs for Floor Scrubbers and Robotic Cleaners: IEC 60335-2-10, IEC 60335-2-2, IEC 62133-1, IP and Transport

Floor cleaners are certified as machines, and their batteries are certified as packs. A scrubber may be a household appliance or a commercial machine; a robot vacuum is an automatic battery-operated cleaner; a robot mop adds water. The correct standard set depends on the machine class, the market and the way the battery is charged. This paper maps the evidence chain and the tests that most often expose a weak NiMH design.

Key facts at a glance

  • IEC 60335-2-10:2021 covers household floor treatment and wet scrubbing machines. Commercial machines use IEC 60335-2-67 or IEC 60335-2-72 depending on traction and class.
  • IEC 60335-2-2:2026 covers vacuum cleaners and automatic battery-operated cleaners. It includes docking stations and battery mode.
  • IEC 62133-1 is the pack safety standard. IEC 61951-2 is the cell performance standard; one does not replace the other.
  • Water is a system test. IPX4 or IPX6 must be verified with the pack installed, the connector mated and the machine in its normal orientation.
  • Commercial machines may fall under machinery safety rules. Traction, steering and braking functions need a risk assessment and, where relevant, safety-related control performance.
  • Transport is mode-specific. UN 3496 for sea; IATA A199 “Not Restricted” for air when conditions are met.

Classify the machine before choosing the standard

MachinePrimary safety standardBattery / chargerNotes
Household vacuum / robot vacuumIEC 60335-2-2:2019 or 2026IEC 62133-1, IEC 60335-2-29 chargerAutomatic cleaners and docks in scope
Household floor scrubber / wet scrubberIEC 60335-2-10:2021IEC 62133-1, charger standardBattery-operated appliances in scope
Commercial floor treatment, no tractionIEC 60335-2-67:2012IEC 62133-1, charger standardCommercial use, risk assessment
Commercial floor treatment with tractionIEC 60335-2-72:2012IEC 62133-1, charger standardTraction drive, ride-on or walk-behind
Robot mop / wet-dry robotIEC 60335-2-2 and IEC 60335-2-10 as applicableIEC 62133-1, IP ratingWater, cleaning agent, dock wash

The classification is not cosmetic. A commercial scrubber may need a machinery risk assessment, emergency stop and braking performance that a household appliance does not. A robot vacuum's dock may be assessed under the appliance standard, but the dock's charger and mains input still need the charger and EMC evidence.

Layer 1: cell performance and pack safety

The cell performance layer uses IEC 61951-2:2017 + A1:2022: capacity, high-rate discharge, cycle life and storage. The pack safety layer uses IEC 62133-1:2017, with the 2026 edition checked for the destination market. The pack tests are external short, impact, crush, overcharge, forced discharge and thermal abuse. For a scrubber pack, the mechanical tests are particularly relevant because the pack is often a large, heavy block that can be dropped or struck during service.

TestScrubber-specific concernRobot-specific concern
External shortLarge pack, high short-circuit currentSmall pack, connector and dock pins
Impact / crushService drop, tank removal, floor impactFall from dock, furniture impact
OverchargeWrong charger, failed termination, hot ambientDock fault, charge while wet
Forced dischargeWeak cell in a long stringSmall string, imbalance
Thermal abuseDirect sunlight, hot floor, enclosure heatDock heater, blocked ventilation

Layer 2: appliance safety to IEC 60335-2-10 and IEC 60335-2-2

IEC 60335-2-10:2021 is the sixth edition for floor treatment machines and wet scrubbing machines. It aligns with IEC 60335-1:2020 and covers battery-operated appliances. The tests that matter most for a NiMH pack are heating, abnormal operation, charging, water ingress and mechanical strength.

  • Heating: brush motor, vacuum motor, pump and pack under continuous scrub load.
  • Abnormal operation: blocked squeegee, dry pump, brush stall, locked fan and recovery tank full.
  • Charging: temperature rise, wrong charger, reverse polarity and termination failure.
  • Water: spillage, recovery tank overflow, hose leakage and cleaning agent compatibility.
  • Mechanical: handle strength, tank retention, wheel impact and pack retention.
Test areaTypical methodBattery interaction
Normal heatingContinuous scrub at rated conditionsPack temperature, connector heat, cell balance
Abnormal vacuumBlocked squeegee or hoseFan current, motor cooling, pack load
Brush stallLocked brush or obstructionPeak current, fuse, controller limit
Pump dry runEmpty tank, closed valvePump current, controller protection
Charging faultWrong charger, failed terminationOvercharge, cell heating, venting
Water spillSpillage on machine and connectorInsulation, corrosion, seal integrity
Certification layers and water safety

Layer 3: commercial machine safety and machinery risk

A ride-on or walk-behind commercial scrubber may be a machine under the EU Machinery Directive 2006/42/EC, now replaced in application by the Machinery Regulation (EU) 2023/1230 from 2027. The risk assessment covers crushing, trapping, steering, braking, emergency stop and battery isolation. Safety-related control functions may need ISO 13849 performance levels. The battery pack is part of the energy source and must be isolatable for maintenance.

HazardExampleEvidence
Crushing / trappingRide-on machine against a wall or rackRisk assessment, bumper, stop distance
Loss of tractionRamp start or wet floorTraction test, brake test, grade rating
ElectricalBattery isolation, charger inletIsolation device, IP rating, insulation test
ThermalPack enclosure in hot plant roomTemperature test, ventilation, derating
MaintenancePack replacement, water tank removalService procedure, lockout, weight limit

Layer 4: IP, EMC, mechanical and transport

Water ingress is the most common cause of scrubber pack failure in the field. IPX4 is a common minimum for splash; IPX6 may be specified for wash-down. The test must be performed with the pack installed and the connector mated, because the connector is often the path of ingress. EMC follows CISPR 14-1/-2 for the machine and charger; a battery pack alone has no intentional RF source, but the motor drives and charger do.

RequirementStandardScope
IP ratingIEC 60529Pack, connector, dock, control panel
EmissionCISPR 14-1 / EN 55014-1Motor drives, charger, electronics
ImmunityCISPR 14-2 / EN 55014-2ESD, surge, transient, RF
VibrationIEC 60068-2-6Transport and machine vibration
DropIEC 60068-2-31Pack and machine handling
Thermal shockIEC 60068-2-14Storage, shipping, wash-down

Charging, water and condensation

A scrubber is often charged in a wet room or after wash-down. The charger interface and pack vent must handle condensation. A sealed pack that breathes through a vent can still accumulate water if the vent is submerged; a pack that is fully sealed can pressurize and leak at the seal. The design should define the vent location, the IP rating and the drying procedure. The charger should not start if the connector is wet or the pack temperature is outside the charge window.

  • Connector: IP-rated, keyed, with a drain path and a cap where practical.
  • Vent: breathable membrane, not a simple hole; protected from direct spray.
  • Condensation: conformal coating on electronics, desiccant where appropriate, and a dry-before-charge instruction.
  • Cleaning agents: compatibility test with the expected detergents and disinfectants.
Water testMethodPass conditionCommon failure
SplashIPX4, oscillating sprayNo harmful ingressConnector gasket, vent path
Wash-downIPX6, strong jetNo harmful ingressSeal compression, latch area
Immersion (if claimed)IPX7, defined depth/timeNo harmful ingressVent, cable gland, connector
CondensationThermal cycling with humidityNo insulation failureBreathable vent placement
Testing and certifying NiMH packs for floor cleaners

Transport and market routes

Mode / marketRequirementEvidence
Sea (IMDG)UN 3496, Class 9Dangerous goods declaration, packaging
Air (IATA)A199 “Not Restricted” when conditions metAir waybill “Not Restricted” + A199
EUCE, EMC, battery regulation, machinery where applicableTechnical file, declaration, risk assessment
UKUKCA, UK EMC, battery rulesDesignated standards, declaration
USAUL 1017 or UL 60335-2-67/2-72 as applicableNRTL report, FCC for charger
JapanPSE charger, appliance safetyPSE certificate, VCCI where applicable
KoreaKC safety and EMCKC certificate
AustraliaRCM, AS/NZS 60335-2-10RCM declaration

Factory audit: ten items for a water-exposed pack

  • Cell traceability: lot, date code, supplier and incoming capacity/resistance test.
  • Welding: pull strength, nugget size and resistance sampling.
  • Cell matching: voltage and resistance grouping for long strings.
  • Pack test: capacity, resistance, cutoff and temperature rise at rated load.
  • Sealing: IP test with connector mated; gasket compression and vent check.
  • Charge test: termination at low and high temperature; wrong-charger test.
  • Mechanical: drop, vibration and connector retention.
  • Chemical: cleaning agent compatibility and corrosion inspection.
  • Marking: chemistry, voltage, capacity, IP rating, warning and traceability.
  • Change control: cell, charger, connector, firmware or enclosure change triggers re-test.
Audit itemFrequencyRecord
Cell incomingEvery lotCapacity, resistance, date code
Weld pullPer shift sampleForce and nugget size
Pack capacity / resistance100%Within tolerance
IP testPer model per quarterNo ingress, connector mated
Charge terminationPer charger lotLow/high temperature pass
Drop / vibrationPer model per quarterNo displacement or loss

Conclusion

Floor scrubbers and robotic cleaners are certified through a combination of appliance safety, pack safety, water ingress, EMC, mechanical and transport evidence. The battery is not a separate accessory; it is part of the machine's energy and water system. A NiMH pack that passes IEC 62133-1 but fails the machine's water test is not certifiable, and a machine that passes the appliance test but ignores the dock pulse is not reliable. The next series moves outdoors to hedge trimmers and chainsaws, where stall torque and garden duty cycles dominate.

Lastest News
Unlock the power of lithium batteries for lasting performance in handheld vacuum cleaners. Weijiang Li-on Battery leads the charge in innovation.
READ MORE
A NiMH battery pack is a collection of individual NiMH batteries connected in series or parallel to create a higher voltage or capacity battery.
READ MORE
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Name*
Whatsapp/Phone
Email*
Message*
Professional battery factory, support OEM & ODM customization.
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Company Name*
Email Address*
WhatsApp / Phone*
Message & Requirements*

Buyer fact sheet

Weijiang Power at a glance

Legal entityShenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power
Founded2010, 16 years of NiMH battery manufacturing
FactoryHuizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops
Capacity200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors
Product rangeNiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells
CertificationsCE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs
Markets60+ countries, focus on Europe and the United States
Order termsNo strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days
Medical NiMHEnglish medical NiMH page
German medical NiMH page

Quick answers for buyers

Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.

What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.

Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.

What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.

How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.

Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ

Language versions: Deutsch · Français · Español

Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.