Paper A of this series mapped the load profile of passenger-coach and high-speed-train emergency systems: reduced aisle and doorway lighting, door control and release, public address and intercom, marker lamps and, on modern EMUs, emergency ventilation and control electronics that must hold up after the main supply drops. Paper B converted that profile into a pack design: the duty-block energy sum, the cold and end-of-life derating, the six-cell 7.2 V string, the -delta V charge and the ride-through hold-up for the EN 50155 S2 and S3 interruption classes. This Paper C is the last step before the vehicle enters service: the type tests and certification that prove the design actually survives the carriage environment, keeps its 90-minute autonomy at the cold end of the range, and meets the EMC, fire and transport rules. The test severities, duty cycles and pass criteria below are taken from the standards and from representative notified-body test reports; exact values on any real certificate always follow the edition and revision printed on that certificate, and all worked pack numbers are illustrative.
Key fact 1. Certification of a carriage emergency pack is a layered chain, not one stamp. The lighting standards UIC 555 (with Amendment 7:2013) and EN 13272-1/-2:2019 define the 90-minute emergency illuminance and the change-over behaviour; EN 50155:2017 defines the electronic equipment environment (temperature class, supply range, interruption class, life class); IEC 61373 defines the shock and vibration spectrum by mounting position; EN 50121-3-2 defines apparatus EMC; EN 45545-2 and -6 define fire behaviour; and the sealed NiMH cells themselves are qualified under IEC 61951-2:2017+A1:2022, IEC 62133-1:2017 (the nickel-system part, note -1) and IEC 63115-2:2021. In the European Union the interoperability pillar is Commission Regulation (EU) No 1302/2014 (TSI LOC&PAS), which references these standards for the rolling-stock subsystem.
Key fact 2. EN 50155:2017 sorts operating temperature into six classes, OT1 to OT6, from OT1 (-25 C to +55 C) for passenger-compartment equipment up to OT6 (-40 C to +85 C) for hot underfloor or traction-adjacent gear. A sealed NiMH emergency module installed inside a carriage wall or under a seat is typically tested to OT1 or OT2, but the cold-end autonomy is the binding point: the cell must still deliver the 90-minute energy after a cold soak at -25 C, not just turn on. The standard also defines life classes L1 to L4 (5 to 20 years, with L4 the default for passenger rolling stock), and supply interruption classes S1 (no interruption), S2 (10 ms) and S3 (20 ms) that the hold-up capacitor, not the battery, must bridge.
Key fact 3. IEC 61373 (edition 2.0, 2010; edition 3.0, 2026, now published) sorts equipment by where it is bolted. Category 1 is body mounted, with Class A for cubicles and Class B for items inside a cubicle; Category 2 is bogie mounted; Category 3 is axle mounted. A distributed NiMH module inside a luminaire or door controller is Category 1 Class B and is tested on the body random-vibration and shock spectra, not the much harsher axle spectrum. The test programme combines a long-life random vibration endurance test, a functional random vibration during which the equipment must still work, and a shock test on each axis.
Key fact 4. EMC for rolling-stock apparatus is EN 50121-3-2. The charger and protection electronics inside the emergency module must survive fast transient bursts of plus or minus 2 kV (5/50 ns, 5 kHz) on supply and signal ports, surges of plus or minus 2 kV line-to-ground and plus or minus 1 kV line-to-line (1.2/50 microsecond), and radio-frequency common-mode immunity over the conducted range; emissions must stay below the apparatus limits. Fire behaviour follows EN 45545-2 for the plastics, insulation, labels and enclosure around the pack, with the operational hazard categories HL1 to HL3 driven by the vehicle kind and zone, and EN 45545-6 for the fire-control and smoke-measurement rules.
Key fact 5. The cell safety and transport layer is separate from the vehicle layer. Sealed NiMH cells are qualified under IEC 62133-1:2017 for safety (the nickel-containing part; IEC 62133-2 is for lithium and does not apply), performance under IEC 61951-2:2017+A1:2022, industrial applications under IEC 63115-2:2021 and mechanical operation under IEC 61959. The packs ship as UN 3496 (batteries containing a strongly alkaline electrolyte) and IATA Special Provision A199 confirms NiMH is not restricted as lithium battery cargo, so they never need the UN 38.3 test summary and never travel under UN 3480 or UN 3481, which belong to lithium-ion.
It helps to read the chain from the outside in. The vehicle operator cares first that the emergency lights actually come on and stay on: UIC 555 requires automatic change-over to the emergency source when the main supply falls below about 0.6 times nominal for more than half a second, then at least 50 percent of normal aisle illuminance and 30 percent in seated areas for 90 minutes; EN 13272-1:2019 adds at least 10 minutes of general lighting for high-speed and long-distance units before the emergency mode steps down, and EN 13272-2:2019 sets a 5 lx escape-route centre-line average and 40 lx at the open vehicle step for urban rail. These are the functional targets the pack must be shown to meet during the type test.
The next layer is the equipment environment. EN 50155:2017 consolidates the conditions electronic gear on rolling stock must withstand: the nominal DC supply (24 V, 72 V, 110 V and the others in EN 50163), the continuous and fluctuation voltage ranges, the temperature class, the temperature-change and damp-heat programmes, the supply interruption classes, and the life class. A local NiMH module inside an emergency luminaire does not see the 110 V bus directly; it is fed by a small EN 50155-qualified DC/DC that holds the charge window across the full bus range, and the module itself is tested as a body-mounted subassembly. The EMC layer is EN 50121-3-2, the mechanical layer is IEC 61373, the fire layer is EN 45545, and the ingress layer is EN 60529 for the luminaire or cabinet rating.
The cell layer is documented separately and travels with the pack as the supplier's technical file. IEC 61951-2 fixes the performance programme for sealed nickel-metal-hydride portable cells, IEC 62133-1 fixes the safety tests (external short circuit, forced discharge, overcharge, abnormal charging), IEC 63115-2 extends the programme to industrial NiMH cells used in equipment, and IEC 61959 fixes the mechanical tests on the cell itself. The train-level battery on the 110 V bus, where it is a vented NiCd or lead-acid block, is a different animal covered by IEC 62973-2 (NiCd) or IEC 62973-3:2024 (lead-acid); the sealed NiMH modules in this article are the local emergency modules and are not certified as the train battery.
| Layer | Standard | What it proves for the NiMH pack |
|---|---|---|
| Functional / lighting | UIC 555 (Amd.7:2013); EN 13272-1/-2:2019 | 90-minute emergency illuminance, 10-minute hold for high-speed stock, change-over at about 0.6 Un |
| Equipment environment | EN 50155:2017; EN 50163 | Temperature class OT1-OT6, supply range, interruption S1/S2/S3, life L1-L4, cold autonomy |
| Mechanical | IEC 61373:2010 (ed.2); ed.3:2026 | Body-mounted category 1 class B random vibration, long-life endurance and shock on three axes |
| EMC | EN 50121-3-2 | Fast transient burst, surge, RF common-mode immunity and emissions for the charger and protection |
| Fire | EN 45545-2; EN 45545-6 | Heat release, smoke and toxicity of plastics, insulation and enclosure around the pack |
| Cell performance / safety | IEC 61951-2:2017+A1:2022; IEC 62133-1:2017; IEC 63115-2:2021; IEC 61959 | Capacity, charge retention, cycle life; short circuit, forced discharge, overcharge safety; mechanical cell tests |
| Transport | UN 3496; IATA A199 | Strongly alkaline electrolyte batteries; NiMH not restricted as lithium cargo; no UN 38.3 required |
EN 50155:2017 is the horizontal standard every rolling-stock electronic cabinet opens with. For an emergency module the binding decisions are the temperature class, the supply range and the interruption class. The six operating classes run from OT1 (-25 C to +55 C) and OT2 (-40 C to +55 C), which are the passenger-compartment and saloon classes most emergency luminaires fall into, through OT3/OT4 to OT5/OT6 that reach +85 C for hot underfloor or traction-adjacent mounting. The cold test is not a warm-on test: the module is thermally stabilised at the cold limit, then required to perform its emergency function - deliver the 90-minute autonomy - at that temperature. The dry heat test holds the equipment at the hot functional limit, the damp-heat test runs a cyclic 40 C / 95 percent humidity programme, and the change-of-temperature test moves the unit between hot and cold chambers to expose seals and connectors.
The electrical envelope is defined against the nominal supply voltages of EN 50163 (24 V, 72 V, 110 V and the rest). The equipment must start up and hold function across the continuous and fluctuation ranges, and it must ride through defined supply interruptions: S1 requires no interruption ride-through, S1 class S2 requires 10 ms and S3 requires 20 ms without the emergency load dropping out. In practice the 10 to 20 ms dip is bridged by a hold-up capacitor on the DC/DC input, not by the NiMH pack; the pack is there for the genuine long outage after the hold-up has decayed. The standard also defines the life class L1 to L4, which frames the expected service duration in years and drives the end-of-life capacity margin built into the pack in Paper B.
/u_file/2610/31/photo/t11ca.gifIEC 61373 sorts equipment by where it is bolted, because an item on the axle sees far more energy than one inside a body-mounted cubicle. Category 1 is body mounted: Class A covers cubicles, subassemblies and components fixed directly on or under the car body, and Class B covers anything mounted inside a cubicle that is itself body mounted. Category 2 is bogie mounted and Category 3 is axle mounted, with progressively harsher random-vibration and shock spectra. A sealed NiMH module inside an emergency luminaire, door controller or PA amplifier is Category 1 Class B: it rides on the body spectrum, but it must still survive the long-life endurance random vibration, the functional random vibration during which the charger and protection must not reset or lose the charge state, and the shock pulses on each of three axes. Welded tabs, cell containment, connector retention and internal component fixation are designed to this spectrum; a module laid out for handheld consumer use will not pass.
| IEC 61373 category | Typical location | Relevance to the emergency NiMH module |
|---|---|---|
| Category 1 Class A | Cubicles and gear fixed to the car body | Cabinet containing emergency control electronics |
| Category 1 Class B | Items inside a body-mounted cubicle | Distributed NiMH module in luminaire / door controller / PA amplifier - the design target |
| Category 2 | Bogie mounted | Not applicable to carriage emergency modules |
| Category 3 | Axle mounted | Not applicable; harshest spectrum reserved for axleborne gear |
EN 50121-3-2 is the apparatus-level EMC standard for rolling stock. The charger and protection electronics in the emergency module are tested for radiated and conducted emissions and for immunity: electrostatic discharge on accessible surfaces, radio-frequency electromagnetic field immunity, fast transient bursts (burst of plus or minus 2 kV, 5/50 ns, 5 kHz) on supply and signal ports, surge immunity (plus or minus 2 kV line-to-ground, plus or minus 1 kV line-to-line, 1.2/50 microsecond), and interruption or dips. The NiMH cell itself is a passive electrochemical component; the EMC risk sits in the switching charger and the protection MOSFET, which is why the layout keeps the charge circuit away from the low-voltage sensing path and provides input filtering.
Fire behaviour follows EN 45545-2 for the materials - the ABS or polycarbonate enclosure, the PCB substrate, the insulation sleeves, the labels and the potting - and EN 45545-6 for the fire-control and smoke-measurement rules; the hazard levels HL1 to HL3 are driven by the vehicle kind, the zone and the category of operation, and a passenger saloon is a higher requirement than an underfloor equipment bay. Ingress protection follows EN 60529: an in-vehicle luminaire may be IP40 or IP44, while a door controller or a module near a gangway may be IP54; the rating is declared on the product and sealed accordingly. The routine maintenance design - the manual test switch, the status indicator and a plug-in module that does not require dismantling the luminaire - is what lets the operator demonstrate readiness over the L4 service life, and the battery management documentation records capacity checks and the end-of-life threshold.
/u_file/2610/31/photo/t11cb.gifThe vehicle tests prove the module as installed; the cell tests prove the chemistry is safe and transportable. IEC 61951-2:2017+A1:2022 sets the performance programme for sealed NiMH portable cells: capacity at standard rate, charge retention after storage, cycle life and low-temperature discharge. IEC 62133-1:2017 is the safety standard for sealed nickel-containing cells (the -1 part; IEC 62133-2 is for lithium and must not be cited on a NiMH declaration), and it covers external short circuit, free fall, thermal abuse, forced discharge and overcharge. IEC 63115-2:2021 extends the programme to industrial NiMH cells used in equipment, which is the right reference for a long-life railway standby module, and IEC 61959 fixes the mechanical tests on the cell itself. The pack-level protection added in Paper B - the 0.9 V per-cell disconnect, the PTC and the resettable fuse - sits on top of the cell safety tests and is documented in the module schematic.
Transport is the easiest layer to get wrong. Sealed NiMH packs are shipped under UN 3496, the UN number for batteries containing a strongly alkaline electrolyte; they are not UN 38.3, and they are never UN 3480 or UN 3481 (lithium-ion). IATA Special Provision A199 explicitly removes NiMH from the lithium-battery cargo restrictions, so air freight does not require the lithium test summary, but the pack still needs the UN 3496 classification, the adequate packing and the dangerous-goods declaration. For the train-level 110 V battery, where the operator specifies vented NiCd or lead-acid, the relevant standards are IEC 62973-2 (NiCd) and IEC 62973-3:2024 (lead-acid); Weijiang supplies the distributed sealed NiMH emergency modules and does not build the train battery.
The pack is tested as a body-mounted electronic subassembly: the environment is EN 50155:2017 (temperature class OT1 or OT2 for saloon gear, life class L4, interruption S2/S3 bridged by the hold-up capacitor), the mechanicals are IEC 61373 category 1 class B, EMC is EN 50121-3-2, fire is EN 45545-2/-6 and the functional target is the 90-minute autonomy in UIC 555 and EN 13272-1/-2. The cells are separately qualified under IEC 61951-2, IEC 62133-1 and IEC 63115-2.
No. Sealed NiMH travels under UN 3496 (batteries with a strongly alkaline electrolyte) and IATA Special Provision A199 confirms NiMH is not restricted as lithium cargo. UN 38.3 and the UN 3480/UN 3481 numbers belong to lithium-ion cells and must not appear on a NiMH shipping document.
For passenger saloon equipment the typical choice is OT1 (-25 C to +55 C) or OT2 (-40 C to +55 C). The binding test is the cold-end autonomy: after stabilising at -25 C the pack must still deliver the 90-minute emergency energy, which is why Paper B sizes against the end-of-life capacity after a cold soak rather than the nameplate.
It is IEC 61373 Category 1 Class B: an item inside a body-mounted cubicle or enclosure. It is not bogie (Category 2) or axle (Category 3) mounted. The welded tabs, connectors and cell containment are designed to the body random-vibration and shock spectra, and the charger must keep its state through the functional vibration test.
The module is fully charged, conditioned at the declared cold temperature, then switched into emergency mode and loaded with the contract emergency load schedule; the test measures that the voltage stays above the pack cut-off and the illuminance threshold for the required duration. The exact load profile follows the vehicle emergency function list and the UIC 555 / EN 13272 illuminance targets; the 13.4 Wh per-zone figure in Paper B is an illustrative example.
The train-level 110 V battery is classically a vented nickel-cadmium or lead-acid block covered by IEC 62973-2 (NiCd) or IEC 62973-3:2024 (lead-acid). The sealed NiMH modules this series covers are the local batteries inside each emergency luminaire, door controller, PA amplifier or control module: smaller, cadmium-free, maintenance-light, and qualified under IEC 61951-2, IEC 62133-1 and IEC 63115-2, shipped under UN 3496.
Functional and autonomy: UIC 555 (Electric lighting in passenger rolling stock, with Amendment 7:2013), including the 50 percent aisle and 30 percent seated-area emergency illuminance, the 90-minute minimum and the change-over at about 0.6 Un for more than half a second; EN 13272-1:2019 (heavy rail, including the 10-minute general-lighting requirement for high-speed and long-distance units) and EN 13272-2:2019 (urban rail, 5 lx escape-route centre-line and 40 lx at the open step); Commission Regulation (EU) No 1302/2014 (TSI LOC&PAS); and the Chinese TB/T 3414 (EMU emergency lighting) and TB/T 3582-2023 (EMU emergency ventilation). Equipment environment: EN 50155:2017 (temperature classes OT1 to OT6, life classes L1 to L4, supply interruption classes S1/S2/S3, damp heat and change of temperature), EN 50163 for supply voltages, EN 60529 for ingress, EN 45545-2 and EN 45545-6 for fire behaviour, EN 50121-3-2 for apparatus EMC and IEC 61373 (edition 2.0, 2010; edition 3.0, 2026) for shock and vibration by mounting category.
Cell and transport references: IEC 61951-2:2017+A1:2022 for sealed NiMH cell performance, IEC 62133-1:2017 for sealed nickel-containing cell safety (the -1 part), IEC 63115-2:2021 for industrial NiMH cells and IEC 61959 for mechanical operation; the IEC 62973 series for rolling-stock auxiliary batteries (IEC 62973-2 NiCd, IEC 62973-3:2024 lead-acid) and GB/T 21413.1 for general rolling-stock equipment conditions; UN 3496 and IATA Special Provision A199 for transport. The test severities and pass criteria reflect the cited standards and representative notified-body test reports; the per-cell cold, end-of-life and depth-of-discharge factors, the 13.4 Wh per-zone energy and all worked pack numbers in this series are illustrative engineering examples, and the binding values are those in the vehicle contract specification and the standards edition printed on the type certificate.
Weijiang Power supplies sealed NiMH packs for OEM carriage emergency modules - emergency LED luminaires, door controllers, passenger address and intercom units and emergency control electronics - designed to the EN 50155 temperature and interruption classes, the IEC 61373 Category 1 Class B body-vibration spectrum, EN 50121-3-2 EMC and EN 45545-2 fire requirements, with welded-tab and fail-safe protection construction and cell-level IEC 61951-2 / IEC 62133-1 / IEC 63115-2 documentation. The packs are cadmium-free and travel under UN 3496 with the IATA A199 path. Send us your bus nominal voltage, emergency load schedule, required autonomy, cold-end temperature class, mounting category and charging arrangement, and we will work through the cell-count, capacity and charge design and support the cold-autonomy, vibration and EMC evidence ahead of the type test. See the Weijiang NiMH product range for standard pack formats, or contact our OEM team with your vehicle specification and emergency load list.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.