An AMR collector or AMI data concentrator is normally mains powered, which hides a subtle requirement: the instant the mains disappears, the grid operator most wants to hear from it. A 'last gasp' - a power-failure message sent before the device goes silent - lets the head-end distinguish a true outage from a communications fault and locate the faulted section. A bare supercapacitor buys a single radio frame; a small nickel-metal hydride module extends that to multiple frames, retries and a store-and-forward window, turning a one-shot notification into a managed outage report.
In an AMI network, meters talk to collectors or data concentrators that aggregate readings and forward them to the head-end over cellular, Ethernet or RF mesh, commonly using the DLMS/COSEM protocol suite of IEC 62056 (with regional companions such as DL/T 698 in China). Meters and their ancillary equipment are type-tested under IEC 62052-11 and related standards, and their immunity to supply dips and interruptions follows IEC 61000-4-11.
Commercial practice shows the established pattern: a smart meter or collector detects mains loss - for example when the rail falls below roughly 80% of nominal for more than a mains cycle - and uses local storage to transmit a last-gasp frame. A representative grid meter, the Aclara SGM3000 series, uses a supercapacitor for short-term timing (a few days of clock keep-alive) and a non-rechargeable lithium backup for longer timing (up to a couple of years), illustrating how different storage durations are deliberately layered.

The first animated figure zooms into the first second after mains loss. The bulk capacitor and a supercapacitor bank - commonly 1-5 farads at 5.5 V - hold the rail long enough for the MCU to detect the event, assemble one frame and key the radio (around 200-500 ms at a transmit current near 250 mA). That is enough for a single best-effort message on a good link, and it is the industry's baseline because it is cheap and needs almost no maintenance.
It is also fragile: if the network is busy, the base station not responding, or the first frame collides, there is no stored energy for a retry, and the head-end never learns the device went dark. A single-frame gasp is a notification, not a reliable report.
The second figure compares what each storage tier delivers. The supercapacitor delivers sub-second, single-frame coverage; a non-rechargeable lithium cell can keep the clock and memory alive for years but is poorly suited to repeated high-current radio pulses; a rechargeable NiMH module delivers seconds to minutes of regulated power - enough to send the last gasp, wait for the acknowledgement, retry across several channels, notify downstream meters, and store context for a 'first gasp' when power returns.
That window is what converts a fire-and-forget pulse into a reliable, acknowledged outage report with retries and a clean power-restart sequence - a meaningful improvement in outage-management-system accuracy for a modest amount of storage.
The choice is the power-versus-energy axis seen across backup design. A supercapacitor is excellent for milliseconds and a few seconds of high power, but its stored energy is small, its voltage droops linearly with charge, and reaching a multi-second, multi-frame window means a bulky, costly bank. Non-rechargeable lithium stores years of energy but is not designed to be repeatedly recharged by the returning mains and is weak on high-current pulses.
Sealed NiMH sits in between: it recharges from the mains rail on every restoration, delivers the radio pulse at low impedance with a flat plateau, survives thousands of outage-charge cycles across a multi-decade deployment, and uses an aqueous chemistry that is safe in a sealed, sun-heated street cabinet with no thermal-management burden.

Concentrators and larger collectors aggregate many meters and often keep a local store-and-forward buffer. For these, the NiMH module acts as a miniature DC-UPS: on outage it finishes the current polling cycle, flushes the buffer and the event log to non-volatile memory, sends last gasps for itself and its downstream nodes, and holds the real-time clock. On restoration it sends a first gasp, reconciles missed intervals and resumes without data loss.
Because outages are (happily) infrequent but the device is mains-connected, the pack lives in an easy duty - kept topped up, discharged only on real events - where NiMH's low self-discharge and cycle robustness are exactly the required attributes.
The design brief records the mains rail and its loss-detection threshold, the radio technology and transmit current, the number of last-gasp frames and acknowledgement/retry window, the buffer-flush and clock-keep-alive needs, and the cabinet temperature range (street cabinets can swing very widely). Paper B turns these into a storage and chemistry calculation; Paper C maps the design onto the IEC 62056, IEC 62052-11 and IEC 61000-4-11 evidence.
Weijiang Power manufactures sealed nickel-metal hydride cells and DC-UPS / last-gasp modules for AMR collectors, data concentrators and smart-grid endpoints. Send us your mains rail, radio technology and transmit current, the number of last-gasp frames and retry window, and the enclosure temperature range, and our engineers will design a welded, wide-temperature NiMH module with charge management and protection. See modules on the products page.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | English medical NiMH page German medical NiMH page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.