Nov.2026 25
Views: 71
What Service and Cleaning Robots Demand from a Battery: Traction, Brush, Vacuum, Pump and Dock Load Profiles
Introduction
A technical load profile for service and cleaning robots: traction, brush, vacuum, pump and dock loads, 24 V, 36 V and 48 V architectures, shift energy, and the honest boundary for sealed NiMH packs.
Details

What Service and Cleaning Robots Demand from a Battery: Traction, Brush, Vacuum, Pump and Dock Load Profiles

A cleaning robot is a mobile appliance with a factory inside it. It drives across a floor, spins one or two brush motors, pulls air or water through a recovery path, lifts dirty water, runs sensors, and docks to charge. The battery sees a traction load, a scrub load, a vacuum load, a pump load and a house load at the same time. The average power sets the energy; the peaks set the connector, fuse and controller.

Key facts at a glance

  • The brush and vacuum motors usually dominate the average load. Traction is important, but on a walk-behind scrubber the two brush motors and the vacuum motor can draw more than the drive system.
  • Peak current arrives at start-up, not at cruise. Brush inrush, vacuum start, pump pressure and simultaneous dock approach can stack.
  • 24 V is the common walk-behind architecture. Larger ride-on machines may use 24 V, 36 V or 48 V, and the current at 24 V is twice the current at 48 V for the same power.
  • Shift energy is a measured duty cycle, not a catalogue runtime. A 24 V 260 Ah flooded pack on a Tennant T500 is about 6.24 kWh nominal; the published 5.9 h runtime implies about 1.06 kW average.
  • Modern high-utilization cleaning robots are increasingly lithium-ion. The installed base still contains flooded lead-acid and AGM. Sealed NiMH is a niche and retrofit chemistry, not the default main pack.
  • NiMH is defensible in small and medium 24 V machines, lead-acid replacement, wide-temperature or abuse-tolerant niches, training units and low-utilization fleets. It is not the right default for a large 24/7 scrubber.

Machine classes and their electrical personalities

“Cleaning robot” covers machines with very different loads. A compact walk-behind scrubber, a ride-on scrubber, a domestic vacuum robot, a window-cleaning robot and a sidewalk delivery robot do not share a battery specification even when they share a 24 V label.

Machine class Typical size Typical voltage Dominant load Battery character
Compact walk-behind scrubber 430–600 mm working width 24 V Brush motors, vacuum, pump, traction Moderate energy, high continuous current, water-safe pack
Ride-on scrubber 700–1,200 mm 24 V, 36 V or 48 V Brush, vacuum, traction, solution/recovery pump High energy, high peak current, opportunity charge or swap
Domestic vacuum robot 300 mm class 14.4 V legacy; Li-ion now Fan, brush, drive, dock Small pack, low cost, low duty, dock charge
Automatic battery cleaner Pool, floor or duct cleaner 18–24 V class Pump, brush, traction Sealed pack, wet environment, docking
Sidewalk delivery robot 10–50 kg payload 18.5–48 V Traction, sensors, compute, thermal High energy density, opportunity charge, lithium default

The table is a starting point. The same 24 V label can describe a 600 W compact scrubber and a 2 kW ride-on machine. The pack must be sized from the actual motor list, not from the nominal voltage.

The mission phases of a cleaning robot

Phase Duration Electrical character Design response
Standby / docked Hours Charger, controller, radio, display Low quiescent drain, charge termination, thermal stability
Drive to start point Seconds to minutes Traction cruise, sensors Energy, connector, speed control
Brush start 0.2–2 s Motor inrush, 3–6× running current Soft start, fuse I²t, controller current limit
Scrubbing cruise Minutes to hours Brush motors plus vacuum plus pump plus traction Continuous thermal design, capacity, voltage sag
Vacuum start / recovery 0.2–3 s Fan inrush, airflow blockage transient Peak current, motor protection, debris screen
Solution / recovery pump Seconds to minutes Pump pressure, valve switching Peak current, dry-run protection, water ingress
Turn / edge / obstacle Seconds Steering or differential drive, brush load change Current headroom, traction control
Dock / charge Minutes to hours Charge current, communication, balancing Charger profile, connector, thermal

The scrub phase is the thermal steady state. The brush start and vacuum start are short, but they decide whether the pack can deliver current without collapsing the controller. A pack that is sized only for average scrub power will trip at the first simultaneous start; a pack sized only for peak current will be heavy and expensive.

24 V five-channel load stack for a compact scrubber

Traction and brush power arithmetic

Traction force is rolling resistance plus grade plus acceleration. For a first estimate on a smooth floor:

F = m × g × (Crr + sinθ) + m × a

Mechanical power is P = F × v. Electrical power is higher by the drive efficiency. Brush power is torque times angular speed. With torque in Nm and speed in rpm:

Pbrush = τ × ω = τ × 2π × rpm / 60

Load case Assumption Mechanical power Electrical estimate Current at 24 V
Compact scrubber traction, 300 kg, flat cruise Crr = 0.02, 1.0 m/s 59 W 75 W at 0.8 efficiency 3.1 A
Same machine, 3% ramp 300 kg, 1.0 m/s 147 W 184 W 7.7 A
Brush motor, 0.55 kW each 2 motors, 80% load 880 W 1,100 W at 0.8 efficiency 45.8 A
Vacuum motor, 0.47 kW Full load 470 W 587 W at 0.8 efficiency 24.5 A
Solution pump, 0.1 kW Pressure duty 100 W 125 W 5.2 A
House load Controller, sensors, lights — 40–80 W 1.7–3.3 A

The table is illustrative. It shows the key point: two 0.55 kW brush motors and one 0.47 kW vacuum motor already exceed 1.5 kW electrical before traction and pump. At 24 V that is more than 60 A continuous, and the start-up peaks are higher. The pack, fuse, wiring and connector must be designed for that, not for a 10 A house load.

Vacuum, pump and dock loads

The vacuum motor is an air machine. Its current rises with airflow and falls as the filter loads or the float closes. A blocked filter can reduce airflow and current, while a broken seal can increase airflow and current. The pump is a water machine. Its current rises with pressure and with viscosity; a dry run can overheat the pump and a blocked line can stall it.

Load Normal behaviour Transient Battery consequence
Vacuum fan Current roughly follows airflow and pressure Start-up inrush; clog release; float closing Peak current and fuse margin; thermal rise
Solution pump Steady pressure, valve switching Dry run, blocked filter, valve opening Current limit, dry-run protection, pack voltage sag
Recovery pump Intermittent, float-controlled Air lock, clog, tank full Repeated peak loads, controller thermal
Squeegee lift Short actuator pulse Mechanical stall at end stop Fuse and actuator protection
Dock handshake Communication, relay, charger Inrush into charger input; contact bounce Connector rating, pre-charge, reverse polarity
Dock charging Constant current then taper Thermal rise at high ambient Charge acceptance, pack cooling, balance

The dock is not a passive accessory. A robot that docks every few minutes sees repeated charge tapering and connector engagement. The pack must accept partial charge, and the charger must communicate with the pack rather than apply a fixed voltage. A sealed pack with no temperature sensing and no charge termination is not a dock-ready pack.

Voltage architectures and full-charge windows

Architecture Nominal Full charge Cutoff Typical use Integration note
24 V lead-acid, 12S 24.0 V 28.8–29.4 V 21.0 V Legacy walk-behind scrubber Heavy, needs full charge and rest
24 V NiMH, 20S 24.0 V 29.0 V at 1.45 V/cell 20.0 V at 1.0 V/cell Small/medium scrubber, retrofit Check controller and charger maximum
24 V LiFePO4, 8S 25.6 V 29.2 V 20.0 V Modern compact scrubber BMS, charger, low-temperature cutoff
24 V NMC, 7S 25.9 V 29.4 V 21.0–24.5 V High-energy compact robot BMS and thermal management required
36 V NiMH, 30S 36.0 V 43.5 V 30.0 V Medium ride-on scrubber Controller absolute maximum must accept 43.5 V
48 V NiMH, 40S 48.0 V 58.0 V 40.0 V Large scrubber or delivery robot 58 V exceeds many 48 V lithium controller limits

The full-charge voltage is the most common integration trap. A 24 V NiMH pack with 20 series cells reaches about 29 V at 1.45 V/cell. A 24 V LiFePO4 pack reaches 29.2 V, which is close, but the charge profile and cutoff are different. A 48 V NiMH pack reaches about 58 V, while a 48 V NMC pack reaches 54.6 V. The controller, charger, DC/DC converter and any accessory rated for a 48 V lithium pack may not accept 58 V. Check the absolute maximum, not the nominal label.

20S NiMH full-charge, nominal and cut-off window

Shift energy: from published runtime to average power

Published runtime is a useful reality check. It converts a nominal pack energy into an average power, and that average power can be compared with the motor list.

Machine Pack Nominal energy Published runtime Implied average power Interpretation
Tennant T500, 260 Ah flooded 24 V, 260 Ah 6.24 kWh 5.9 h 1.06 kW Brush + vacuum + traction + pump at part load
Tennant T500, 260 Ah, heavy mode 24 V, 260 Ah 6.24 kWh 4.9 h 1.27 kW Higher brush pressure and vacuum duty
Kärcher B 40 W Bp, 115 Ah 24 V, 115 Ah 2.76 kWh 3.5 h 0.79 kW Compact machine, lower brush and vacuum load
Illustrative 24 V 100 Ah NiMH 24 V, 100 Ah 2.40 kWh 3.0 h 0.80 kW Feasible if the motor list and duty match
Illustrative 24 V 66 Ah NiMH 24 V, 66 Ah 1.58 kWh 2.0 h 0.79 kW Small machine or low-utilization fleet

The Tennant T500 numbers are published with a 260 Ah flooded battery. The implied 1.06 kW average is a sanity check, not a measured motor sum. The actual instantaneous power can be much higher. The Kärcher B 40 W Bp with a 115 Ah battery and 3.5 h maximum runtime implies about 0.79 kW average. Those two machines sit in different power classes even though both are 24 V.

Chemistry boundaries: lead-acid, lithium-ion and sealed NiMH

Attribute Flooded / AGM lead-acid Lithium-ion Sealed NiMH Cleaning-robot meaning
Energy density Low; heavy High Moderate NiMH is lighter than lead-acid in large cells, heavier than lithium
Cycle life Moderate; sensitive to depth and Partial State of Charge High with BMS Moderate; sensitive to heat and overcharge NiMH fits single-shift and moderate-cycle fleets
Partial charge Poor; needs full charge and rest Excellent Fair; needs periodic full charge and balance Opportunity charging favours lithium
Temperature Tolerant but loses capacity; gassing Needs thermal management Tolerant; heat shortens life NiMH fits hot or unheated rooms with simple thermal design
Water and wash-down Requires watering and ventilation Sealed but sensitive to ingress Sealed; tolerant of humid rooms NiMH suits wet floors if the enclosure and connector are sealed
Cost and maintenance Low initial, high maintenance High initial, low maintenance Moderate initial, low maintenance NiMH is a maintenance-free retrofit option
Weight and swap Very heavy; battery room Light; fast swap Moderate to heavy; assisted swap NiMH favours fixed-pack machines

The honest market statement: new high-utilization cleaning robots use lithium-ion because energy density, opportunity charging and cycle life decide the economics. The installed base still runs flooded lead-acid because the machines were designed around it and the battery room exists. Sealed NiMH has a real but narrower role: a small or medium 24 V machine, a lead-acid replacement where the customer wants a sealed maintenance-free pack, a wide-temperature or abuse-tolerant niche, training units and low-utilization fleets. It should not be marketed as a universal replacement for a lithium main pack.

What the load profile means for pack selection

Load finding Pack consequence What to ask the supplier
Continuous 60–80 A at 24 V High-rate cells, thick current path, thermal path Continuous and 10 s current rating at 25 °C and 45 °C
Brush inrush 3–6× running current Controller current limit, fuse I²t, low resistance Short-circuit current and internal resistance data
Vacuum start and clog transient Peak current margin, motor protection Peak current for 1 s and 10 s
Frequent dock charging Charge acceptance, balance, temperature sensing Charge profile, termination, temperature limits
Wet floor and wash-down IP enclosure, connector, condensation drain IP rating, immersion test, drain design
Hot ambient or cold store Derating, charge inhibit, thermal insulation Temperature derating curves and charge limits
Single shift vs 24/7 Energy capacity vs cycle life and opportunity charge Cycle life at partial state of charge
Retrofit into a lead-acid machine Voltage window, charger, weight, ballast Full-charge voltage, cutoff, charger compatibility

RFQ load audit checklist

  • Machine class and working width: compact walk-behind, ride-on, domestic robot, automatic cleaner, delivery robot.
  • Motor list: each brush, vacuum, pump, traction, steering and actuator; rated power, running current, start-up current and duration.
  • Simultaneous load: which motors run together, and which start at the same time.
  • Duty cycle: scrub time, transport time, idle time, dock time, number of docks per shift.
  • Energy per shift: measured Ah or Wh, or published runtime with the exact battery capacity and mode.
  • Voltage window: nominal, full charge, cutoff, controller absolute maximum, charger maximum, DC/DC input range.
  • Environment: wet floor, wash-down, humidity, ambient temperature, dust, chemicals, storage temperature.
  • Mechanical: pack mass, dimensions, centre of gravity, lifting, connector retention, vibration, drop.
  • Compliance: IEC 60335-2-10 or 2-2 or 2-67/2-72, IEC 62133-1, IP, EMC and UN 3496.

Conclusion

A service or cleaning robot battery is not selected by nominal voltage and ampere-hour alone. The brush and vacuum motors set the continuous current; the starts set the peak; the shift and dock pattern set the energy and charge acceptance; the wet environment sets the enclosure and connector. Sealed NiMH can serve the smaller 24 V machines, the lead-acid retrofit and the wide-temperature niche if the pack is designed with high-rate cells, a real thermal path, a sealed enclosure and a charger that understands the chemistry. It cannot be sold as a universal drop-in for a modern lithium cleaning robot.

Lastest News
Unlock the power of lithium batteries for lasting performance in handheld vacuum cleaners. Weijiang Li-on Battery leads the charge in innovation.
READ MORE
A NiMH battery pack is a collection of individual NiMH batteries connected in series or parallel to create a higher voltage or capacity battery.
READ MORE
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Name*
Whatsapp/Phone
Email*
Message*
Professional battery factory, support OEM & ODM customization.
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Company Name*
Email Address*
WhatsApp / Phone*
Message & Requirements*

Buyer fact sheet

Weijiang Power at a glance

Legal entityShenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power
Founded2010, 16 years of NiMH battery manufacturing
FactoryHuizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops
Capacity200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors
Product rangeNiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells
CertificationsCE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs
Markets60+ countries, focus on Europe and the United States
Order termsNo strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days
Medical NiMHEnglish medical NiMH page
German medical NiMH page

Quick answers for buyers

Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.

What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.

Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.

What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.

How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.

Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ

Language versions: Deutsch · Français · Español

Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.