A NiMH pack for a cleaning robot is a current-delivery system that happens to store energy. The machine spends most of its shift pulling 40–80 A from a 24 V pack, then docks and charges in a wet room. The specification must cover the motor starts, the continuous scrub load, the voltage window, the water ingress path and the charge profile. This paper is a six-step sizing method for sealed NiMH packs in that environment.
| Load | Data to collect | Why it matters | Typical 24 V result |
|---|---|---|---|
| Brush motor 1 | Rated W, running A, start-up A and duration | Continuous and peak current | 0.55 kW, about 23 A running, 80–140 A start |
| Brush motor 2 | Same as above | Simultaneous load | Adds another 23 A running |
| Vacuum motor | Rated W, airflow, start-up A | Continuous and start-up peak | 0.47 kW, about 20 A running |
| Traction motor | Rated W, grade, acceleration | Peak during ramp start | 100–400 W, 4–17 A |
| Solution / recovery pump | Rated W, pressure, duty | Intermittent peak | 50–150 W, 2–6 A |
| Actuators | Squeegee, brush lift, valves | Short transient | 20–100 W pulses |
| House load | Controller, sensors, lights, radio | Continuous drain | 20–80 W, 1–3 A |
| Dock / charger | Charge current, communication, termination | Thermal and balance | 10–30 A charge, 4–8 h |
The load audit must state whether currents are measured or calculated, at what voltage, and at what temperature. A motor nameplate gives rated input, not start-up current. A clamp meter on the battery cable gives the real sum, including house load and simultaneity. If no measurement is possible, use the motor datasheet and a 3–6× start-up factor for brushed motors, then verify on the first prototype.
| Architecture | Series cells | Nominal | Full charge | Cutoff | Best use |
|---|---|---|---|---|---|
| 24 V NiMH | 20S | 24.0 V | 29.0 V | 20.0 V | Compact walk-behind, domestic robot, retrofit |
| 36 V NiMH | 30S | 36.0 V | 43.5 V | 30.0 V | Medium ride-on, lower current than 24 V |
| 48 V NiMH | 40S | 48.0 V | 58.0 V | 40.0 V | Large machine, high power, but 58 V integration barrier |
| 24 V lead-acid reference | 12S | 24.0 V | 28.8–29.4 V | 21.0 V | Legacy machine, charger and ballast designed for it |
| 24 V LiFePO4 reference | 8S | 25.6 V | 29.2 V | 20.0 V | Modern compact machine with BMS |
| 48 V NMC reference | 13S | 48.1 V | 54.6 V | 39.0 V | Modern high-utilization machine |
Choose the lowest voltage that keeps the continuous current within the connector, wiring and controller ratings, and that keeps the full-charge voltage within the controller's absolute maximum. A 24 V 2 kW machine draws about 83 A before efficiency; a 48 V machine draws about 42 A. Higher voltage reduces current and I²R loss, but it also changes the charger, converter and safety practice. Do not change voltage architecture without auditing the whole electrical system.

| Cell format | Nominal capacity | Approx. energy per cell | Configuration for 24 V 100 Ah | Pack implication |
|---|---|---|---|---|
| D, 3.3 Ah | 3.3 Ah | 3.96 Wh | 20S30P, 600 cells | Heavy, many welds, high assembly cost |
| F, 10 Ah | 10 Ah | 12 Wh | 20S10P, 200 cells | Better packaging, fewer connections |
| M, 20 Ah | 20 Ah | 24 Wh | 20S5P, 100 cells | Good for medium packs, robust busbar |
| Prismatic, 50 Ah | 50 Ah | 60 Wh | 20S2P, 40 cells | Compact, fewer joints, needs fixture |
| Prismatic, 100 Ah | 100 Ah | 120 Wh | 20S1P, 20 cells | Simplest pack, large cells and busbars |
Small D cells are convenient for prototypes but poor for a 2.4 kWh pack: 600 cells mean hundreds of welds and a heavy assembly. Large F, M or prismatic cells reduce part count and improve current path. The trade-off is tooling, fixture design and minimum order quantity. For a 24 V 66 Ah pack, 20S20P D cells or 20S3P M cells are realistic; for 100 Ah, prefer fewer, larger cells.
| Derating factor | Typical effect | What to measure | Design response |
|---|---|---|---|
| Discharge rate | 5–20% loss at 1–3C | Capacity at the actual continuous current | Use high-rate cells, larger capacity |
| Temperature | 10–25% loss at 0 °C; more at −10 °C | Capacity and resistance vs temperature | Insulation, heater, charge inhibit |
| Age and cycling | 10–20% loss at end of life | Cycle life to 80% capacity | Size for end-of-life, not beginning |
| Cutoff voltage | 5–15% unusable if cutoff is high | Controller cutoff and cell mismatch | Low-voltage disconnect, per-string monitoring |
| Wiring and connector | 2–5% loss at high current | Cable gauge, connector resistance | Short paths, busbars, rated connectors |
| Balance and mismatch | 3–10% in a series string | Cell capacity spread, temperature spread | Sorting, balancing, conservative cutoff |
A 24 V 100 Ah nameplate pack may deliver only 60–75 Ah at the actual current, temperature and end-of-life condition. That is why the runtime calculation must use a derated capacity. If the machine needs 3.0 h at 0.8 kW, the nominal energy requirement is 2.4 kWh; with a 70% derating, the nameplate pack must be about 3.4 kWh, or 24 V 142 Ah. That is a different product, and it changes mass and cost.

| Pack | Internal resistance | Current | Voltage sag | Heat in the pack |
|---|---|---|---|---|
| 24 V 100 Ah NiMH, large cells | 20 mΩ | 60 A | 1.2 V | 72 W |
| 24 V 100 Ah NiMH, large cells | 20 mΩ | 120 A | 2.4 V | 288 W |
| 24 V 66 Ah NiMH, D cells | 40 mΩ | 60 A | 2.4 V | 144 W |
| 24 V 66 Ah NiMH, D cells | 40 mΩ | 120 A | 4.8 V | 576 W |
| 24 V 100 Ah lead-acid | 15–25 mΩ | 60 A | 0.9–1.5 V | 54–90 W |
| 24 V 50 Ah LiFePO4 | 10–20 mΩ plus BMS | 60 A | 0.6–1.2 V | 36–72 W |
The voltage sag must leave enough headroom for the controller and the motor. If the controller cuts off at 20 V and the pack sags 4.8 V at 120 A from a 24 V nominal, the available voltage is below 20 V before the cells are empty. That is a false cutoff, not a capacity problem. The fix is lower resistance, a larger pack, a shorter cable or a controller with a lower cutoff. Heat is the other issue: 576 W inside a sealed box needs a real thermal path, not a plastic shell and a sticker.
| Hazard | Design measure | Verification | Common failure |
|---|---|---|---|
| Spray and splash | IPX4 enclosure, sealed lid, gasket | IEC 60529 hose test | Gasket compressed by a poorly toleranced lid |
| Wash-down | IPX6 or IPX6K, drain path, breather | Jet test, pressure and duration | Water trapped between cells and enclosure |
| Temporary immersion | IPX7 if the application requires it | Immersion test at stated depth and time | Connector not sealed; water enters through pins |
| Condensation | Breather membrane, desiccant, drain plug | Temperature cycling with humidity | Breathing pulls humid air into a cold pack |
| Connector | Sealed, keyed, touch-safe, rated for current | Mating cycles, wet mating test | Connector rated for 30 A used at 80 A |
| Pressure | Pressure equalisation, no trapped air | Altitude and thermal cycling | Enclosure bulges or pulls water through seals |
| Chemical attack | Detergent-resistant materials | Chemical compatibility test | Cleaning agent cracks the lid or gasket |
IP rating is not a complete water strategy. A pack can pass an IPX4 test and still fail in service because the connector is not sealed, the lid gasket creeps, or condensation forms during nightly cooldown. Design a drain path, use a breather membrane, and test the complete pack with the production connector and cable, not a bare enclosure.
| Charging topic | NiMH requirement | Cleaning-robot implication |
|---|---|---|
| Charge profile | Constant current, then voltage/temperature termination | Do not use a lead-acid or lithium charger without a NiMH profile |
| Termination | −ΔV, dT/dt, time limit, temperature limit | False termination in hot ambient; false peak in cold |
| Overcharge | Trickle only at low current with temperature control | Dock idle time can overheat a sealed pack |
| Balance | Periodic full charge; cell matching | Partial opportunity charging needs a scheduled full charge |
| Temperature | Charge inhibit outside the specified window | Do not charge a cold pack or a hot pack after wash-down |
| Communication | Pack temperature, voltage, status to charger | Dock must stop on fault, not rely on a timer |
A NiMH pack is not “maintenance-free” if it is charged without temperature sensing. The charger must see the pack, and the pack must be able to stop the charge. A simple timer charger is acceptable only for a known, fixed pack and a known ambient, and even then it needs a thermal cutoff. In a cleaning robot that docks in a wet room, the charger is part of the safety system.
| Parameter | Value | Basis |
|---|---|---|
| Brush motors | 2 × 0.55 kW | Tennant T500 class |
| Vacuum motor | 0.47 kW | Same class |
| Traction and pump | 0.3 kW combined average | Application estimate |
| House load | 50 W | Controller, sensors, lights |
| Average electrical load | 1.92 kW | Sum at part load |
| Required runtime | 3.0 h | Single shift with transport |
| Energy at the pack | 5.76 kWh | Average × time |
| Derated usable fraction | 70% | Rate, temperature, age, cutoff |
| Nameplate energy | 8.23 kWh | 5.76 / 0.70 |
| 24 V nameplate capacity | 343 Ah | 8.23 kWh / 24 V |
| Continuous current | 80 A | 1.92 kW / 24 V |
| Peak current | 160–200 A for 1–3 s | Brush and vacuum starts |
This example is deliberately conservative. A 24 V 343 Ah NiMH pack is large and heavy; it may not fit the machine or make economic sense against lithium. That is the point of the calculation: it shows whether NiMH is viable before a prototype is built. For a smaller 1.0 kW average and a 2 h runtime, the same method yields about 2.86 kWh nameplate, or 24 V 119 Ah, which is a realistic NiMH pack. The chemistry fits the smaller machine, not the large one.
| Failure | Cause | Prevention | Detection |
|---|---|---|---|
| False low-voltage cutoff | Voltage sag at high current | Lower resistance, larger pack, shorter cable | Log pack voltage and current during brush start |
| Overheating in a sealed box | High continuous current, no thermal path | Cell spacing, heat spreader, ventilation or derating | Thermistors at cell centre and surface |
| Water ingress | Connector or lid leak | Sealed connector, gasket, drain, IP test | Humidity sensor, insulation resistance |
| Cell mismatch | Poor sorting, repeated partial charge | Sorting, periodic full charge, balance | Per-string voltage during charge and discharge |
| Charge termination failure | Hot ambient, no dT/dt | Temperature limit, charger communication | Pack temperature and charge time |
| Connector overheating | Undersized contacts, high current | Rated connector, busbar, thermal test | Connector temperature rise |
| Mechanical fatigue | Vibration, drop, heavy cells | Fixture, potting, shock mounts | Vibration and drop test |
Sealed NiMH is a credible pack chemistry for a small or medium cleaning robot when the load audit is honest, the cell format is chosen for current rather than convenience, the capacity is derated, the enclosure is water-safe and the charger understands NiMH. It is not a shortcut around system engineering. The six steps in this paper are the minimum gate between a catalogue cell and a pack that survives a wet floor, a brush start and a dock every day.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | English medical NiMH page German medical NiMH page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.