Selecting and Sizing Sealed NiMH Packs for Service and Cleaning Robots: Load Audit, 24 V Architecture, Water-Safe Design, Derating and Charging
Introduction
A six-step method for specifying sealed NiMH packs in service and cleaning robots: load audit, 24 V/36 V architecture, high-rate cell configuration, derating, water-safe mechanical design and charging.
Details

Selecting and Sizing Sealed NiMH Packs for Service and Cleaning Robots: Load Audit, 24 V Architecture, Water-Safe Design, Derating and Charging

A NiMH pack for a cleaning robot is a current-delivery system that happens to store energy. The machine spends most of its shift pulling 40–80 A from a 24 V pack, then docks and charges in a wet room. The specification must cover the motor starts, the continuous scrub load, the voltage window, the water ingress path and the charge profile. This paper is a six-step sizing method for sealed NiMH packs in that environment.

Key facts at a glance

  • Start with the motor list, not the ampere-hour label. Brush, vacuum, pump, traction and actuator currents determine the pack.
  • 24 V is the mainstream walk-behind architecture. A 20S NiMH pack gives 24 V nominal, about 29 V full charge and 20 V cutoff.
  • Continuous current is the first filter. A 0.55 kW brush pair plus a 0.47 kW vacuum can draw more than 60 A at 24 V before traction.
  • Derating is not optional. Rate, temperature, age, cutoff and wiring can remove 25–45% of the nameplate capacity.
  • Water-safe design is mechanical, not only a label. IP rating, connector sealing, condensation drain and pressure equalisation all matter.
  • NiMH fits small and medium 24 V machines and retrofits. For a large 24/7 scrubber, lithium-ion is the better default.

Step 1: Load audit from machine data to pack spec

Load Data to collect Why it matters Typical 24 V result
Brush motor 1 Rated W, running A, start-up A and duration Continuous and peak current 0.55 kW, about 23 A running, 80–140 A start
Brush motor 2 Same as above Simultaneous load Adds another 23 A running
Vacuum motor Rated W, airflow, start-up A Continuous and start-up peak 0.47 kW, about 20 A running
Traction motor Rated W, grade, acceleration Peak during ramp start 100–400 W, 4–17 A
Solution / recovery pump Rated W, pressure, duty Intermittent peak 50–150 W, 2–6 A
Actuators Squeegee, brush lift, valves Short transient 20–100 W pulses
House load Controller, sensors, lights, radio Continuous drain 20–80 W, 1–3 A
Dock / charger Charge current, communication, termination Thermal and balance 10–30 A charge, 4–8 h

The load audit must state whether currents are measured or calculated, at what voltage, and at what temperature. A motor nameplate gives rated input, not start-up current. A clamp meter on the battery cable gives the real sum, including house load and simultaneity. If no measurement is possible, use the motor datasheet and a 3–6× start-up factor for brushed motors, then verify on the first prototype.

Step 2: Choose the voltage architecture

Architecture Series cells Nominal Full charge Cutoff Best use
24 V NiMH 20S 24.0 V 29.0 V 20.0 V Compact walk-behind, domestic robot, retrofit
36 V NiMH 30S 36.0 V 43.5 V 30.0 V Medium ride-on, lower current than 24 V
48 V NiMH 40S 48.0 V 58.0 V 40.0 V Large machine, high power, but 58 V integration barrier
24 V lead-acid reference 12S 24.0 V 28.8–29.4 V 21.0 V Legacy machine, charger and ballast designed for it
24 V LiFePO4 reference 8S 25.6 V 29.2 V 20.0 V Modern compact machine with BMS
48 V NMC reference 13S 48.1 V 54.6 V 39.0 V Modern high-utilization machine

Choose the lowest voltage that keeps the continuous current within the connector, wiring and controller ratings, and that keeps the full-charge voltage within the controller's absolute maximum. A 24 V 2 kW machine draws about 83 A before efficiency; a 48 V machine draws about 42 A. Higher voltage reduces current and I²R loss, but it also changes the charger, converter and safety practice. Do not change voltage architecture without auditing the whole electrical system.

20S NiMH cell string for a 24 V cleaning pack

Step 3: Select the cell format and configuration

Cell format Nominal capacity Approx. energy per cell Configuration for 24 V 100 Ah Pack implication
D, 3.3 Ah 3.3 Ah 3.96 Wh 20S30P, 600 cells Heavy, many welds, high assembly cost
F, 10 Ah 10 Ah 12 Wh 20S10P, 200 cells Better packaging, fewer connections
M, 20 Ah 20 Ah 24 Wh 20S5P, 100 cells Good for medium packs, robust busbar
Prismatic, 50 Ah 50 Ah 60 Wh 20S2P, 40 cells Compact, fewer joints, needs fixture
Prismatic, 100 Ah 100 Ah 120 Wh 20S1P, 20 cells Simplest pack, large cells and busbars

Small D cells are convenient for prototypes but poor for a 2.4 kWh pack: 600 cells mean hundreds of welds and a heavy assembly. Large F, M or prismatic cells reduce part count and improve current path. The trade-off is tooling, fixture design and minimum order quantity. For a 24 V 66 Ah pack, 20S20P D cells or 20S3P M cells are realistic; for 100 Ah, prefer fewer, larger cells.

Step 4: Derate the nameplate capacity

Derating factor Typical effect What to measure Design response
Discharge rate 5–20% loss at 1–3C Capacity at the actual continuous current Use high-rate cells, larger capacity
Temperature 10–25% loss at 0 °C; more at −10 °C Capacity and resistance vs temperature Insulation, heater, charge inhibit
Age and cycling 10–20% loss at end of life Cycle life to 80% capacity Size for end-of-life, not beginning
Cutoff voltage 5–15% unusable if cutoff is high Controller cutoff and cell mismatch Low-voltage disconnect, per-string monitoring
Wiring and connector 2–5% loss at high current Cable gauge, connector resistance Short paths, busbars, rated connectors
Balance and mismatch 3–10% in a series string Cell capacity spread, temperature spread Sorting, balancing, conservative cutoff

A 24 V 100 Ah nameplate pack may deliver only 60–75 Ah at the actual current, temperature and end-of-life condition. That is why the runtime calculation must use a derated capacity. If the machine needs 3.0 h at 0.8 kW, the nominal energy requirement is 2.4 kWh; with a 70% derating, the nameplate pack must be about 3.4 kWh, or 24 V 142 Ah. That is a different product, and it changes mass and cost.

Derating chain from nameplate capacity to usable runtime

Step 5: Check internal resistance, voltage sag and heat

Pack Internal resistance Current Voltage sag Heat in the pack
24 V 100 Ah NiMH, large cells 20 mΩ 60 A 1.2 V 72 W
24 V 100 Ah NiMH, large cells 20 mΩ 120 A 2.4 V 288 W
24 V 66 Ah NiMH, D cells 40 mΩ 60 A 2.4 V 144 W
24 V 66 Ah NiMH, D cells 40 mΩ 120 A 4.8 V 576 W
24 V 100 Ah lead-acid 15–25 mΩ 60 A 0.9–1.5 V 54–90 W
24 V 50 Ah LiFePO4 10–20 mΩ plus BMS 60 A 0.6–1.2 V 36–72 W

The voltage sag must leave enough headroom for the controller and the motor. If the controller cuts off at 20 V and the pack sags 4.8 V at 120 A from a 24 V nominal, the available voltage is below 20 V before the cells are empty. That is a false cutoff, not a capacity problem. The fix is lower resistance, a larger pack, a shorter cable or a controller with a lower cutoff. Heat is the other issue: 576 W inside a sealed box needs a real thermal path, not a plastic shell and a sticker.

Step 6: Design the water-safe enclosure and connector

Hazard Design measure Verification Common failure
Spray and splash IPX4 enclosure, sealed lid, gasket IEC 60529 hose test Gasket compressed by a poorly toleranced lid
Wash-down IPX6 or IPX6K, drain path, breather Jet test, pressure and duration Water trapped between cells and enclosure
Temporary immersion IPX7 if the application requires it Immersion test at stated depth and time Connector not sealed; water enters through pins
Condensation Breather membrane, desiccant, drain plug Temperature cycling with humidity Breathing pulls humid air into a cold pack
Connector Sealed, keyed, touch-safe, rated for current Mating cycles, wet mating test Connector rated for 30 A used at 80 A
Pressure Pressure equalisation, no trapped air Altitude and thermal cycling Enclosure bulges or pulls water through seals
Chemical attack Detergent-resistant materials Chemical compatibility test Cleaning agent cracks the lid or gasket

IP rating is not a complete water strategy. A pack can pass an IPX4 test and still fail in service because the connector is not sealed, the lid gasket creeps, or condensation forms during nightly cooldown. Design a drain path, use a breather membrane, and test the complete pack with the production connector and cable, not a bare enclosure.

Charging and balance for a NiMH cleaning pack

Charging topic NiMH requirement Cleaning-robot implication
Charge profile Constant current, then voltage/temperature termination Do not use a lead-acid or lithium charger without a NiMH profile
Termination −ΔV, dT/dt, time limit, temperature limit False termination in hot ambient; false peak in cold
Overcharge Trickle only at low current with temperature control Dock idle time can overheat a sealed pack
Balance Periodic full charge; cell matching Partial opportunity charging needs a scheduled full charge
Temperature Charge inhibit outside the specified window Do not charge a cold pack or a hot pack after wash-down
Communication Pack temperature, voltage, status to charger Dock must stop on fault, not rely on a timer

A NiMH pack is not “maintenance-free” if it is charged without temperature sensing. The charger must see the pack, and the pack must be able to stop the charge. A simple timer charger is acceptable only for a known, fixed pack and a known ambient, and even then it needs a thermal cutoff. In a cleaning robot that docks in a wet room, the charger is part of the safety system.

Worked example: 24 V compact scrubber

Parameter Value Basis
Brush motors 2 × 0.55 kW Tennant T500 class
Vacuum motor 0.47 kW Same class
Traction and pump 0.3 kW combined average Application estimate
House load 50 W Controller, sensors, lights
Average electrical load 1.92 kW Sum at part load
Required runtime 3.0 h Single shift with transport
Energy at the pack 5.76 kWh Average × time
Derated usable fraction 70% Rate, temperature, age, cutoff
Nameplate energy 8.23 kWh 5.76 / 0.70
24 V nameplate capacity 343 Ah 8.23 kWh / 24 V
Continuous current 80 A 1.92 kW / 24 V
Peak current 160–200 A for 1–3 s Brush and vacuum starts

This example is deliberately conservative. A 24 V 343 Ah NiMH pack is large and heavy; it may not fit the machine or make economic sense against lithium. That is the point of the calculation: it shows whether NiMH is viable before a prototype is built. For a smaller 1.0 kW average and a 2 h runtime, the same method yields about 2.86 kWh nameplate, or 24 V 119 Ah, which is a realistic NiMH pack. The chemistry fits the smaller machine, not the large one.

Failure modes to design out

Failure Cause Prevention Detection
False low-voltage cutoff Voltage sag at high current Lower resistance, larger pack, shorter cable Log pack voltage and current during brush start
Overheating in a sealed box High continuous current, no thermal path Cell spacing, heat spreader, ventilation or derating Thermistors at cell centre and surface
Water ingress Connector or lid leak Sealed connector, gasket, drain, IP test Humidity sensor, insulation resistance
Cell mismatch Poor sorting, repeated partial charge Sorting, periodic full charge, balance Per-string voltage during charge and discharge
Charge termination failure Hot ambient, no dT/dt Temperature limit, charger communication Pack temperature and charge time
Connector overheating Undersized contacts, high current Rated connector, busbar, thermal test Connector temperature rise
Mechanical fatigue Vibration, drop, heavy cells Fixture, potting, shock mounts Vibration and drop test

RFQ checklist for a cleaning-robot NiMH pack

  • Machine and duty: class, working width, motor list, simultaneous load, runtime, docks per shift.
  • Voltage: nominal, full charge, cutoff, controller absolute maximum, charger maximum.
  • Current: continuous, 10 s peak, 1 s peak, start-up duration, fuse and connector rating.
  • Energy: measured Wh per shift, derating assumptions, end-of-life capacity.
  • Environment: wet floor, wash-down, humidity, ambient and storage temperature, chemicals.
  • Mechanical: dimensions, mass limit, centre of gravity, fixture, connector type, mating cycles.
  • Charging: profile, termination, communication, balance, charge time, opportunity-charge window.
  • Safety and compliance: IEC 62133-1, IEC 60335-2-10 or 2-2 or 2-67/2-72, IP, EMC, UN 3496.
  • Documentation: test report, UN 38.3 summary, MSDS, cell datasheet, pack drawing, traceability.

Conclusion

Sealed NiMH is a credible pack chemistry for a small or medium cleaning robot when the load audit is honest, the cell format is chosen for current rather than convenience, the capacity is derated, the enclosure is water-safe and the charger understands NiMH. It is not a shortcut around system engineering. The six steps in this paper are the minimum gate between a catalogue cell and a pack that survives a wet floor, a brush start and a dock every day.

Lastest News
Unlock the power of lithium batteries for lasting performance in handheld vacuum cleaners. Weijiang Li-on Battery leads the charge in innovation.
READ MORE
A NiMH battery pack is a collection of individual NiMH batteries connected in series or parallel to create a higher voltage or capacity battery.
READ MORE
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Name*
Whatsapp/Phone
Email*
Message*
Professional battery factory, support OEM & ODM customization.
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Company Name*
Email Address*
WhatsApp / Phone*
Message & Requirements*

Buyer fact sheet

Weijiang Power at a glance

Legal entityShenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power
Founded2010, 16 years of NiMH battery manufacturing
FactoryHuizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops
Capacity200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors
Product rangeNiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells
CertificationsCE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs
Markets60+ countries, focus on Europe and the United States
Order termsNo strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days
Medical NiMHEnglish medical NiMH page
German medical NiMH page

Quick answers for buyers

Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.

What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.

Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.

What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.

How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.

Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ

Language versions: Deutsch · Français · Español

Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.